Cable Mode
16 DigiTrak
®
MFCB™ Operator’s Manual
Reference Yaw Manual Entry Key Pad
Enter the reference yaw value in this screen by using the direction buttons to highlight a number and the
execute button to select it. Enter the value for reference yaw one digit at a time left to right; then select
the curved arrow to set it. For example if you want to set 76.5° as the reference yaw, select 7, then 6,
then 5, and then select the curved arrow. You will be returned to the Eclipse SST Main Display with the
new reference yaw displayed.
When the SST Transmitter’s yaw matches the reference yaw, the transmitter is considered to be “on-line”
and a screen such as the following will display.
Eclipse SST Main Display (On-Line)
The SST can also be used with an Eclipse receiver to take depth readings and for Target Steering. See
the Eclipse System operator’s manual and the SST System operator’s manual for more information.
“Exit” (highlighted)
exits the menu with no
change
Backspace deletes
the last number
entered
Numbers for the
reference yaw
display here as
they are entered
SST on Reference Line
Curved arrow
(Execute) sets the
reference yaw