User's Manual

Cable Mode
DigiTrak
®
MFCB Operator’s Manual 17
Target Steering
When a target depth has been programmed into the receiver and the remote is receiving telemetry data,
the following screen will display.
SST Target Steering Display
If a standard Eclipse Cable transmitter is used, the screen will display as above but without the yaw data
and the roll will display by clock position as opposed to the 360 indicator shown here. See the Target
Steering Display in the Remote Mode section.
Roll Offset
The roll offset function is only available in cable-mode. It is used when the transmitter’s 12 o’clock slot
does not match the drill head’s 12 o’clock position.
To access the roll offset menu, push the right direction button,
, from the Eclipse Cable or SST Main
Display. The Roll Offset Menu will appear.
SST’s Deviation from
Reference Yaw
Actual SST Yaw