User's Manual

Receiver
32 DigiTrak
®
SEOperator’s Manual
When the roll offset function is used (an electronic compensation to match the
transmitter’s 12 o’clock position to the drill head’s 12 o’clock position), the roll
indicator will have a hollow dot and the letters RO for roll offset at the bottom right,
as shown here. For more information on the roll offset, see "Units & Roll Offset
Menu" above.
The roll/pitch update meter displays the quantity of roll/pitch data being received
from the transmitter. When the meter is empty, no roll/pitch data is being received, and all information will
disappear on both the receiver and remote display. Depth and predicted depth readings may still be
taken, but the receiver will assume the transmitter has a pitch of zero, as indicated by the following image
appearing on the depth or predicted depth mode screen.
Pitch Assumed Zero
Depth Mode Screen
From the locate mode screen, hold in the trigger to access the depth mode screen. This screen shows
the battery status of the transmitter. It also provides a depth reading and other data about the position of
the transmitter with respect to the receiver.
Receiver Depth Mode Screen at LL with HAG on (Trigger In)
Approximate
Locate Point
(FLP or RLP)
HAG Setting
Line-in-the-box at
Locate Line (LL)
Depth of
Transmitter
Transmitter
Battery Status