Installation guide

Displaying Configuration Information Online
Example 6–1 System Configuration Display
>>> show config
Return
Console T2.4-2859 VMS PALcode X5.12F, OSF PALcode X1.09B
CPU 0 P B2001-AA DECchip (tm) 21064-2
CPU 1 -
Memory 0 P B2002-DA 128 MB
Memory 1 -
Memory 2 -
Memory 3 -
Ethernet 0 P 08-00-2B-1D-02-8F
Ethernet 1 P 08-00-2B-1D-02-90
ID 0 ID 1 ID 2 ID 3 ID 4 ID 5 ID 6 ID 7
A SCSI P RZ57 Host
BP
C DSSI P RF72 Host
D SCSI P RZ35 RZ35 RZ35 Host
E SCSI P TLZ04 Host
Futurebus+ P - - ----
System Status Pass Type b to boot
>>>
Module, network component, or mass storage bus label
Component’s status after last self-test: either ‘P’’ for pass or
‘‘F’ for fail.
Description of the component: describes modules, provides
Ethernet addresses, and lists the devices on each mass
storage bus.
System Configuration 6–11