User`s guide
of the SW300 enclosure is required, grasp the sheet metal base assembly on
the side and carefully lift it.
4. Retain the shipping container and all packing materials.
2.4 Placing the SW300 Enclosure
Use the following procedure to move the SW300 enclosure to its designated site:
WARNING
To prevent damage to the SW300 enclosure and injury to personnel, make
sure to provide a clear path for the casters.
1. Roll the SW300 enclosure to its installation location.
2. If required, depress the lock on each front caster to prevent the SW300
enclosure from moving.
2.5 Power Cords
Note
The SW300 enclosure is not shipped with power cords.
You need to supply your own power cords. Order country-specific 13-20 amp input
power cords, as listed in Table 2–1.
Table 2–1 Country-Specific Power Cords
Country Voltage Amperes Plug
Meters
(Feet) Order No.
Australia 250 V ac 16 AS 3112 - 1981 2.5 (8.2) BN05C–2E
Canada 125 V ac 13 NEMA 5–15 2.4 (8.0) BN20A–2E
Central Europe 250 V ac 16 CEE 7/7 (Schuko) 2.5 (8.2) BN03F–2E
Denmark 250 V ac 16 Afsnit 107 2.5 (8.2) BN27K–2E
Europe–Central 250 V ac 16 CEE 7/7 (Schuko) 2.5 (8.2) BN03F–2E
India 250 V ac 16 BS 546 2.5 (8.2) BN27P–2E
Ireland 250 V ac 13 BS 1363 2.5 (8.2) BN02C–2E
Israel 250 V ac 16 SI 32 2.5 (8.2) BN24U–2E
Italy 250 V ac 16 CEI 23–16/VII 2.5 (8.2) BN27J–2E
Japan 125 V ac 13 NEMA 5–15 2.4 (8.0) BN20A–2E
New Zealand 250 V ac 16 AS 3112—1981 2.5 (8.2) BN05C–2E
South Africa 250 V ac 16 BS 546 2.5 (8.2) BN27P–2E
Switzerland 250 V ac 16 SEV 1011 2.5 (8.2) BN27G–2E
United Kingdom 250 V ac 13 BS 1363 2.5 (8.2) BN02C–2E
United States 125 V ac 13 NEMA 5–15 3.0 (9.8) BN20A–2E
2–4 Unpacking and Installation Instructions