User`s guide

Power
4.5 Power Supply Replacement
4.5.2 Replacing a BBU
WARNING
Always use both hands when removing or replacing an SBB, to fully
support its weight.
To replace a BBU in slot 6, complete the following procedure:
1. Press the two mounting tabs to release the unit, and slide the unit out of the
shelf.
2. Insert the replacement unit in the guide slots and push it in until the tabs
lock in place.
3. Observe the LEDs and ensure the BBU is charging as specified in Table 2–2.
The BBU should be fully charged in approximately 1 hour.
4.6 Power Cords and Cables
Each BA35X–HA universal input ac power supply requires an individual ac
power cord that is compatible with an International Electronic Committee (IEC)
C–14 shrouded ac receptacle connector. These cords are part of the enclosure and
are listed in the enclosure documentation.
CAUTION
Input ac power must be routed through the enclosure cable distribution
unit. This ensures proper line voltage protection for the supply. Do not
connect an ac supply directly to a wall outlet.
Each BA35X–HB universal input dc power requires an individual dc power cable
that has a plug receptacle (Molex part number 39–01–2060) and six female
pins (Molex part number 39–00–0055). The receptacle wiring is described in
Table 4–4.
Table 4–4 DC Power Receptacle Wiring
Pin No. Signal Pin No. Signal
1 +48 Vdc 4 +48 Vdc RTN
2 BAT_STAT H 5 Not used
3 ENABLE H 6 SIGNAL RTN
4–6 Power