User`s guide

Figure 4–12 Program Card and Its Eject Button (ESD Shield)
CXO-4333A-MC
PROGRAM CARD
EJECT BUTTON
HSJ40
PROGRAM CARD
Use the following procedures to replace your program cards in the event that you
wish to load new firmware or if you had to remove the program card for some
reason:
Program Card Upgrade—Nonredundant Configuration
An HS operating firmware upgrade causes a brief interruption in service to
attached drives. The operating system should automatically recover from this
outage within a few seconds after the new firmware becomes operational and
restores service.
Use the following procedure to upgrade the firmware (replace the program card)
in a nonredundant controller:
1. Locate the controller to be shut down.
2. Attach an ESD grounding strap to your wrist at one end and to a cabinet
grounding stud at the other end.
3. Remove the ESD shield over the program card by pulling the two plastic
push/pull pins on each side of the shield.
4. Press the program card eject button to eject the old program card from the
controller.
5. Remove the program card.
4–28 Installation