6. While holding the OCP reset (//) button, insert the new program card,
pressing the card in until the eject button extends outward almost even
with the program card, then release the reset (//) button. The controller
restarts.
Note
Following the controller restart, approximately 60 seconds pass before
the controller accepts CLI commands. This delay does not affect unit
availability to the host. The delay provides time for controller internal
configuration operations to complete before user commands change that
configuration.
If the controller initializes correctly, the green reset LED will begin to flash
one time per second. If an error occurs during initialization, the OCP will
display a code.
7. Replace the ESD shield over the program card by pushing the two plastic
push pins on each side of the shield.
8. Remove the ESD grounding strap.
Program Card Upgrade—Dual-Redundant Configuration
In dual-redundant configurations, the firmware in both controllers must be
upgraded simultaneously.
Use the following procedure to upgrade the firmware (replace the program cards)
of a dual-redundant controller configuration:
1. Attach an ESD grounding strap to your wrist at one end and to a cabinet
grounding stud at the other end.
2. Remove the ESD shields over both program cards by pulling the two plastic
push/pull pins on each side of the two shields.
3. Press the program card eject buttons on both controllers simultaneously and
remove both old program cards.
4. Press and hold the OCP reset (//) buttons on both controllers while inserting
new program cards. Be sure the eject buttons extend outward almost even
with the edge of the cards.
5. Release the reset (//) buttons. Both controllers will restart.
The two controllers will reinitialize concurrently and will synchronize with
each other. The timing of this procedure is not critical, except that the
program cards should be removed and inserted at approximately the same
time (within an interval of a few seconds).
Note
Following the controller restart, approximately 60 seconds pass before
the controller accepts CLI commands. This delay does not affect unit
availability to the host. The delay provides time for controller internal
configuration operations to complete before user commands change that
configuration.
Installation 4–29