User`s guide

exercisers. There are additional commands used to run local programs such
as, CFMENU, FLS, and so forth.
Remember these two rules when using the CLI:
Not all configuration parameters need to be specified on one line. They can be
entered by using multiple SET commands.
Only enough of each command needs to be entered to make the command
unique (usually three characters). For example, SHO is equivalent to SHOW.
5.2.3 How to Exit CLI
If you are using a maintenance terminal, you cannot exit the CLI. Entering the
EXIT command merely restarts the CLI and redisplays the controller type, and
the last fail error information as shown in Example 5–1:
Example 5–1 CLI EXIT Command Message
CLI> EXIT
Copyright Digital Equipment Corporation 1993, 1995. All rights reserved.
HSJ40 Firmware version V25J, Hardware version 0000
Last fail code: 018800A0
Press " ?" at any time for help.
CLI>
If you are using a DUP connection for the CLI, type EXIT after the CLI prompt
to return control to the host.
If you are connected to a virtual terminal via DUP for OpenVMS, and you
specified the /LOG qualifier on your command line, a log file of your session in
CLI is created. You must use the EXIT command to exit the CLI in order to print
the log file.
5.2.4 Setting Configuration Parameters for a Nonredundant Controller
Configuration
If you have a nonredundant controller configuration, perform the following steps
at initial installation (or when replacing a failed controller module) to set up your
controllers configuration parameters from the CLI.
Define the configuration in the following order from a maintenance terminal
connected to the terminal port connector on the front bezel of your controller.
Not all steps are applicable to each controller model. Therefore, each step in the
following procedure lists applicable models for that step.
CAUTION
Do not install the host port cables for your new controller until after you
have set all of the initial parameters. Failure to follow this process may
result in adverse effects on the host/cluster. Follow the specific rules for
your controller model regarding the application of power when installing
host cables.
5–6 Controller Operations