User`s guide

Turns on the fault (amber) LED on the front upper right corner of the SW300
cabinet
Activates an audible alarm
Increases the speed of the blowers
Figure 5–5 shows the EMU front panel LEDS which display information when
the subsystem is turned on or encounters a problem.
Figure 5–5 EMU Front Panel LEDs and Switches
5
6
7
8
BLOWERS
BLOWERS
1
2
3
4
AUDIBLE
ALARM SWITCH
SYSTEM OK
TEMPERATURE
SHELF FAULT
CXO-4310A-MC
5.8.2 Controller Fault Detection
If the controller detects a storage device failure/fault, or a fault in the other
controller in a dual-redundant configuration, it illuminates the fault (amber)
LED on the EMU. When a special ‘‘controller alive’’ signal from either controller
indicates to the EMU that a controller is not functioning, the EMU does the
following:
Turns on its fault (amber) LED
Turns off its System OK (green) LED
Activates an audible alarm
The HSZ40–Bx controller generates an error message on the maintenance
terminal when it detects one of the following fault conditions:
A power supply SBB has failed
A blower has failed or is either not installed or not connected
The operating temperature is too high
Controller Operations 5–25