User`s guide

HSJ> SHOW RAIDSETS FULL
Name Storageset Uses Used by
------------------------------------------------------------------------------
RAID0 raidset DISK100 D0
DISK300
DISK400
DISK500
Switches:
POLICY (for replacement) = BEST_PERFORMANCE
RECONSTRUCT (priority) = NORMAL
CHUNKSIZE = 128 blocks
State:
RECONSTRUCT 3% complete on member DISK500
DISK100 (member 0) is RECONSTRUCTING
DISK300 (member 1) is RECONSTRUCTING
DISK400 (member 2) is RECONSTRUCTING
DISK500 (member 3) is RECONSTRUCTING
Size: 2050353 blocks
Enter the following CLI command to display information about a particular
RAIDset:
HSJ> SHOW RAID0
Name Storageset Uses Used by
------------------------------------------------------------------------------
RAID0 raidset DISK100 D0
DISK300
DISK400
DISK500
Switches:
POLICY (for replacement) = BEST_PERFORMANCE
RECONSTRUCT (priority) = NORMAL
CHUNKSIZE = 128 blocks
State:
NORMAL
DISK100 (member 0) is NORMAL
DISK300 (member 1) is NORMAL
DISK400 (member 2) is NORMAL
DISK500 (member 3) is NORMAL
Size 2050353 blocks
Enter the following CLI command to display all information about all stripesets
known to the controller:
HSJ> SHOW STRIPESETS FULL
Name Storageset Uses Used by
------------------------------------------------------------------------------
STRIPE0 stripeset DISK110 D1
DISK210
DISK310
Switches:
CHUNKSIZE = 128 blocks
State:
NORMAL
DISK110 (member 0) is NORMAL
DISK210 (member 1) is NORMAL
DISK310 (member 2) is NORMAL
Size: 2050353
6–12 Working with RAID Arrays