User`s guide

7
Diagnostics and Utilities
This chapter contains descriptions and instructions for running the following HS
array controller local programs and for using command disks:
DILX
TILX
VTDPY
FLS
CONFIGURE (CONFIG)
CFMENU utility
Code Patch/Code Patch (CLCP) utility
CLONE utility
Command disks
C_SWAP utility and FMU are not described in this chapter. Refer to Section 5.11
for information regarding the Controller Warm Swap (C_SWAP) utility. Refer to
the StorageWorks Array Controller HS family of Array Controllers Service Manual
for instructions for using the Fault Management utility (FMU).
For error reporting information, refer to the StorageWorks Array Controller HS
Family of Array Controllers Service Manual.
7.1 Initialization Diagnostics
Any of the following actions cause the controller to initialize:
A power-up cycle
A firmware reset
Pressing the reset (//) button on the controller’s OCP
A host clear
During a controller initialization sequence, the controller diagnostics run
automatically. Refer to Section 5.1 for a complete description of the initialization
diagnostics.
If a hard failure occurs anytime during the initialization sequence, the controller
OCP LEDs indicate an error. An error is displayed at the maintenance terminal
the next time the prompt is returned. If no message displays, press the Return
key on the terminal’s keyboard and the error message should display.
Diagnostics and Utilities 7–1