User`s guide
Example 7–4 (Cont.) Using Auto-Configure with the All Units Option
Are you sure you want to continue (y/n) [n] ?y
Enter execution time limit in minutes (1:65535) [60] ?
Enter performance summary interval in minutes (1:65535) [60] ?
Unit 10 successfully allocated for testing
Unit 12 successfully allocated for testing
Unit 14 successfully allocated for testing
Unit 21 successfully allocated for testing
Unit 23 successfully allocated for testing
Unit 61 successfully allocated for testing
Unit 63 successfully allocated for testing
DILX testing started at: 13-JAN-1994 04:42:39
Test will run for 60 minutes
Type ^T(if running DILX through VCS) or ^G(in all other cases)
to get a current performance summary
Type ^C to terminate the DILX test prematurely
Type ^Y to terminate DILX prematurely
DILX Summary at 13-JAN-1994 04:44:11
Test minutes remaining: 59, expired: 1
Unit 10 Total IO Requests 9595
No errors detected
Unit 12 Total IO Requests 5228
No errors detected
Unit 14 Total IO Requests 10098
No errors detected
Unit 21 Total IO Requests 9731
No errors detected
Unit 23 Total IO Requests 5230
No errors detected
Unit 61 Total IO Requests 11283
No errors detected
Unit 63 Total IO Requests 5232
No errors detected
Reuse Parameters (stop, continue, restart, change_unit) [stop] ?
DILX - Normal Termination
HSJ>
7.3.2.5 Using Auto-Configure on an HSZ40 Array Controller
Example 7–5 shows a DILX run on an HSZ40 array controller when the Auto-
Configure option was chosen. This example also shows some error messages.
Example 7–5 Using Auto-Configure on an HSZ Controller
HSZ> SHOW DEVICE
Name Type Port Targ Lun Used by
------------------------------------------------------------------------------
DISK100 disk 1 0 0 D0
DISK110 disk 1 1 0 D1
DISK130 disk 1 3 0 D2
DISK140 disk 1 4 0 D3
DISK150 disk 1 5 0 D4
DISK440 disk 4 4 0 D5
(continued on next page)
7–12 Diagnostics and Utilities