User`s guide

Example 7–5 (Cont.) Using Auto-Configure on an HSZ Controller
HSZ> RUN DILX
Disk Inline Exerciser - version 2.0
It is recommended that DILX only be run when there is no host activity
present on the HSZ. Do you want to continue (y/n) [n]?y
The Auto-Configure option will automatically select, for testing,
all of the disk units configured. It will perform a very thorough test with
*WRITES* enabled. The user will only be able to select the run time and
performance summary options. The user will not be able to specify specific
units to test. The Auto-Configure option is only recommended for initial
installations.
Do you wish to perform an Auto-Configure (y/n) [n] ?y
**** C a u t i o n ****
All data on the Auto-Configured disks will be destroyed.
You *MUST* be sure of yourself.
Are you sure you want to continue (y/n) [n] ?y
Enter execution time limit in minutes (1:65535) [60] ?
Enter performance summary interval in minutes (1:65535) [60] ?
Unit 0 successfully allocated for testing
Unit 1 successfully allocated for testing
Unit 2 successfully allocated for testing
Unit 3 successfully allocated for testing
Unit 4 successfully allocated for testing
Unit 5 successfully allocated for testing
Maximum number of units are now configured
DILX testing started at: 13-JAN-1994 04:36:17
Test will run for 60 minutes
Type ^G to get a current performance summary
Type ^C to terminate the DILX test prematurely
Type ^Y to terminate DILX prematurely
The unit status and/or the unit device type changed unexpectedly.
Unit 5 dropped from testing
DILX Summary at 13-JAN-1994 04:40:48
Test minutes remaining: 56, expired: 4
Cnt err in HEX IC:03F00402 PTL:00/00/FF Key:06 ASC/Q:A1/00 HC:1 SC:0
Total Cntrl Errs Hard Cnt 1 Soft Cnt 0
Unit 0 Total IO Requests 29779
No errors detected
Unit 1 Total IO Requests 15810
No errors detected
Unit 2 Total IO Requests 15816
No errors detected
Unit 3 Total IO Requests 15816
No errors detected
Unit 4 Total IO Requests 15816
No errors detected
Unit 5 Total IO Requests 4035
Err in Hex: IC 0326450A PTL:04/04/00 Key:04 ASC/Q:80/06 HC:2 SC:0
Err in Hex: IC 0328450A PTL:04/04/00 Key:04 ASC/Q:03/00 HC:1 SC:0
Total Errs Hard Cnt 3 Soft Cnt 0
The unit status and/or the unit device type changed unexpectedly.
Unit 5 dropped from testing
DILX - Normal Termination
(continued on next page)
Diagnostics and Utilities 7–13