User`s guide

Example 7–6 (Cont.) Using the All Units Option on an HSZ40 Controller
Write enable disk unit(s) to be tested (y/n) [n] ?y
The write percentage will be set automatically.
Enter read percentage for Random IO and Data Intensive phase (0:100) [67] ?
Enter data pattern number 0=ALL, 19=USER_DEFINED, (0:19) [0] ?
Perform initial write (y/n) [n] ?y
Perform data compare (y/n) [n] ?y
Enter compare percentage (1:100) [5] ?
Disk unit numbers on this controller include:
0
1
2
3
4
5
Enter unit number to be tested ?0
Unit 0 will be write enabled.
Do you still wish to add this unit (y/n) [n] ?y
Enter start block number (0:3124637) [0] ?
Enter end block number (0:3124637) [3124637] ?
Unit 0 successfully allocated for testing
Select another unit (y/n) [n] ?y
Enter unit number to be tested ?1
Unit 1 will be write enabled.
Do you still wish to add this unit (y/n) [n] ?y
Enter start block number (0:832316) [0] ?
Enter end block number (0:832316) [832316] ?
Unit 1 successfully allocated for testing
Select another unit (y/n) [n] ?n
DILX testing started at: 13-JAN-1994 04:47:17
Test will run for 10 minutes
Type ^G to get a current performance summary
Type ^C to terminate the DILX test prematurely
Type ^Y to terminate DILX prematurely
DILX Summary at 13-JAN-1994 04:49:08
Test minutes remaining: 9, expired: 1
Unit 0 Total IO Requests 25190
Read Count 0 Write Count 25190
KB xfer Read 0 Write 201520 Total 201520
No errors detected
Unit 1 Total IO Requests 6398
Read Count 0 Write Count 6398
KB xfer Read 0 Write 51184 Total 51184
No errors detected
Reuse Parameters (stop, continue, restart, change_unit) [stop] ?
DILX - Normal Termination
HSZ>
7.3.2.7 Using All Defaults on an HSZ40 Array Controller
Example 7–7 shows a DILX run on an HSZ40 array controller without using the
Auto-Configure option and using the all defaults option.