Example 7–7 Using All Defaults on an HSZ40 Controller
HSZ> RUN DILX
Disk Inline Exerciser - version 2.0
It is recommended that DILX only be run when there is no host activity
present on the HSZ. Do you want to continue (y/n) [n]?y
The Auto-Configure option will automatically select, for testing,
all of the disk units configured. It will perform a very thorough test with
*WRITES* enabled. The user will only be able to select the run time and
performance summary options. The user will not be able to specify specific
units to test. The Auto-Configure option is only recommended for initial
installations.
Do you wish to perform an Auto-Configure (y/n) [n] ?n
Use all defaults and run in read only mode (y/n) [y]?y
Disk unit numbers on this controller include:
0
1
2
3
4
5
Enter unit number to be tested ?0
Unit 0 successfully allocated for testing
Select another unit (y/n) [n] ?y
Enter unit number to be tested ?4
Unit 4 successfully allocated for testing
Select another unit (y/n) [n] ?n
DILX testing started at: 13-JAN-1994 04:52:56
Test will run for 10 minutes
Type ^G to get a current performance summary
Type ^C to terminate the DILX test prematurely
Type ^Y to terminate DILX prematurely
DILX Summary at 13-JAN-1994 04:54:45
Test minutes remaining: 9, expired: 1
Cnt err in HEX IC:03164002 PTL:01/00/00 Key:04 ASC/Q:89/00 HC:2 SC:0
Total Cntrl Errs Hard Cnt 2 Soft Cnt 0
Unit 0 Total IO Requests 251
Err in Hex: IC 0326450A PTL:01/00/00 Key:03 ASC/Q:80/00 HC:1 SC:0
Err in Hex: IC 02110064 PTL:01/00/00 Key:01 ASC/Q:18/02 HC:0 SC:2
Err in Hex: IC 0326450A PTL:01/00/00 Key:01 ASC/Q:18/8B HC:0 SC:2
Total Errs Hard Cnt 1 Soft Cnt 7
Unit 4 Total IO Requests 2101
No errors detected
Reuse Parameters (stop, continue, restart, change_unit) [stop] ?
DILX - Normal Termination
HSZ>
Refer to the StorageWorks™ Array Controllers HS Family of Array Controllers
Service Manual for more details for running DILX.