User`s guide
7.3.3.2 Interrupting TILX Execution
Use the following guidelines to interrupt TILX execution.
Note
The circumflex symbol (^) is equivalent to the Ctrl key. You must press
and hold the Ctrl key and type the character key given.
Note
Do not use Ctrl/G from a VCS, because it causes VCS to terminate. VCS
acts on the sequence, and the sequence never gets sent to TILX. Use
Ctrl/T when interrupting TILX from a VCS.
• Ctrl/G causes TILX to produce a performance summary. TILX continues
normal execution without affecting the run-time parameters.
• Ctrl/C causes TILX to produce a performance summary, stop testing, and
prompt the reuse parameters question.
• Ctrl/Y causes TILX to terminate. The reuse parameters question is not
prompted.
• Ctrl/T causes TILX to produce a performance summary. TILX then continues
executing normally without affecting any of the run-time parameters.
7.3.3.3 Running TILX
TILX prompts a series of questions needed to collect the parameters to perform
a TILX test. Enter ‘‘Y’’ to use the defaults for TILX (most of the other TILX
questions are not prompted). Enter ‘‘N’’ and the defaults are not used. You
must then answer each question as it is displayed. For more details and a list
of defaults, refer to the StorageWorks Array Controllers HS Family of Array
Controllers Service Manual.
TILX has the following three tests:
• Basic function test
• User-Defined test
• Read-Only test
For details of these tests refer to StorageWorks Array Controllers HS Family of
Array Controllers Service Manual.
7.3.4 TILX Examples
The following sections present two TILX examples, one using all functions, the
other using all defaults. A read-only test example is not shown.
7–18 Diagnostics and Utilities