User`s guide

Example 7–8 (Cont.) Using All Functions
Unit 50 Total IO Requests 724
Read Count 3 Write Count 681 Reposition Count 3
Total KB xfer 6718 Read 10 Write 6707
No errors detected
Unit 52 Total IO Requests 731
Read Count 3 Write Count 687 Reposition Count 3
Total KB xfer 6743 Read 10 Write 6733
No errors detected
Reuse Parameters (stop, continue, restart, change_unit) [stop] ?
TILX - Normal Termination
HSJ>
7.3.4.2 Using All Defaults
In Example 7–9, all defaults are chosen for TILX. This is a semiextensive test,
even though the test only runs for 10 minutes. The only function not performed
is data compares. Data compare operations are time-consuming operations with
tape drives. TILX is invoked from a maintenance terminal.
CAUTION
TILX should be run ONLY using scratch tapes. This test writes to the
tape and destroys any data that exists.
Example 7–9 Using All Defaults
HSJ> SHOW TAPE
Name Type Port Targ Lun Used by
------------------------------------------------------------------------------
TAPE500 tape 5 0 0 T50
TAPE520 tape 5 2 0 T52
HSJ> RUN TILX
Tape Inline Exerciser - version 1.0
Use all defaults (y/n) [y] ?
Tape unit numbers on this controller include:
50
52
Enter unit number to be tested ?50
Is a tape loaded and ready, answer Yes when ready ?y
Unit 50 successfully allocated for testing
Select another unit (y/n) [n] ?y
Enter unit number to be tested ?52
Is a tape loaded and ready, answer Yes when ready ?y
Unit 52 successfully allocated for testing
Maximum number of units are now configured
(continued on next page)
7–20 Diagnostics and Utilities