There are no entities eligible for initialization.
Explanation: You chose to initialize a device or storageset, but there are
currently no devices or storagesets that are eligible to be initialized. Tapes,
CD–ROMs, loaders, and passthrough devices may not be initialized. Optical
memory devices, stripesets, and RAIDsets may be initialized, but only if they
are not already configured as a unit. Disks may be initialized only if they
are not already configured as a unit or as part of a storageset, spareset, or
failedset.
There are no entities eligible to be added as units.
Explanation: You chose to add a unit, but there are no devices or storagesets
that are eligible to become units. Tape and CD–ROM devices (HSJ- and
HSD30 array controller only) can be added as units unless they are already
configured as units. Passthrough containers (HSJ- and HSD30 array
controllers only) also can be added as units unless they are already configured
as units. Disks, optical memory, stripesets, and RAIDsets must first be
initialized before they can be added as units. Disks may not be made into
units if they are currently in the spareset or the failedset.
There are no mirrorsets eligible for changing membership count.
Explanation: You chose to change the membership count of a mirrorset, but
there are no mirrorsets eligible for this operation. To be eligible, a mirrorset
must be associated with a unit and must not already have the maximum
number of members allowed for a mirrorset.
There are no reduced RAIDset/mirrorset units with NOPOLICY set.
Explanation: You chose to replace a member of a reduced RAIDset.
CFMENU is unable to find any RAIDsets that are eligible for a manual
replacement. In order to be eligible, the RAIDset must be configured as a
unit, it must be in a reduced state, and it must have the NOPOLICY switch
set.
There are no storageset units with members that can be moved to the
FAILEDSET.
Explanation: You chose to move a device from a storageset to the
FAILEDSET, but there are no devices eligible for that operation. Eligible
devices must be members of RAIDsets or mirrorsets that are associated with
a unit. If the device is a member of a RAIDset, it must not be a reduced
RAIDSET. If the device is a member of a mirrorset, removing the device from
the mirrorset must leave at least one member of the mirrorset in a normal
state.
There are no units to delete.
Explanation: You chose to delete a unit, but there are no units configured
on the controller.
Unable to allocate memory, CFMENU terminating.
Explanation: There is not enough memory available for CFMENU to run.
User has not picked enough eligible devices to complete the storageset.
Explanation: You chose to create a stripeset or a RAIDset and specified how
many members to use, but when CFMENU prompted for devices, you did not
select enough to complete the storageset.