User`s guide
Type ^Y or ^C (then RETURN) at any time to abort Code Patch.
Type ^Z (then RETURN) at any prompt to choose the default for
the remaining questions.
Version: [V15J ]?
WARNING
The patch you are entering is not for the current firmware
version (XLZ6 ). The patch you are entering is for firmware
version V15J .
This patch will NOT be applied to the current firmware.
Length: [10]?
Patch Type: [0]?
Patch Number: [1]?
Count: [1]?
Address: [00000099]?
Value[ 0] [00000000]? 1
Count: [0]?
Verification: [39D6C0BB]?
The patch you have just entered is not applied until
the controller firmware is changed to Version XLZ6 .
Code Patch Main Menu
0: Exit
1: Enter a Patch
2: Delete Patches
3: List Patches
Enter option number (0..3) [0] ?
Specifying a Correct Patch Number for Deletion
The following is an example of what happens when you specify the correct patch
number for your firmware version.
CLI> RUN CLCP
Select an option from the following list:
Code Load & Code Patch local program Main Menu
0: Exit
1: Enter Code LOAD local program
2: Enter Code PATCH local program
Enter option number (0..2) [0] ? 2
----------------------------------------------------------------------
You have selected the Code Patch local program. This program is
used to manage firmware code patches. Select an option from the
following list:
Type ^Y or ^C (then RETURN) at any time to abort Code Patch.
Code Patch Main Menu
0: Exit
1: Enter a Patch
2: Delete Patches
3: List Patches
Enter option number (0..3) [0] ? 2
Diagnostics and Utilities 7–83