User`s guide

Some subcodes and all controller-dependent information is not decoded by ERF.
Instructions for how to decode this information is contained in the StorageWorks
Controllers HS Family of Array Controllers Service Manual. Example 8–2 is an
example of an OpenVMS VAX error log that did not decode the subcodes and the
controller dependent information.
Example 8–2 OpenVMS VAX ERF Error Log That Did Not Decode Fully
MSLG$W_EVENT 040A
CONTROLLER ERROR
UNKNOWN SUBCODE #0020(X)
MSLG$Q_CNT_ID 30300019
01280001
UNIQUE IDENTIFIER, 000130300019(X)
MASS STORAGE CONTROLLER
MODEL = 40.
MSLG$B_CNT_SVR FF
CONTROLLER SOFTWARE VERSION #255.
MSLG$B_CNT_HVR 00
CONTROLLER HARDWARE REVISION #0.
CONTROLLER DEPENDENT INFORMATION
LONGWORD 1. 030A0000
/..../
LONGWORD 2. 24010102
/...$/
LONGWORD 3. 00000000
/..../
LONGWORD 4. 7BDF0000
/..ß{/
LONGWORD 5. 00000000
/..../
LONGWORD 6. 01000000
/..../
LONGWORD 7. 00004200
/.B../
LONGWORD 8. 00000000
/..../
LONGWORD 9. 00000000
/..../
LONGWORD 10. 00000000
/..../
LONGWORD 11. 00000000
/..../
LONGWORD 12. 00000000
/..../
LONGWORD 13. 00000000
/..../
LONGWORD 14. 00000000
/..../
LONGWORD 15. 4F4C0000
/..LO/
ERF does not recognize (translate) devices or their device-specific extended error
status. However, ERF does decode basic MSCP and TMSCP reported error
packets from the HSJ or HSD30 array controller.
8–12 Operating System Support