User`s guide

ADD UNIT
second controller will inherit any PREFERRED_PATH settings, and the
two controllers will operate using the preset PREFERRED_PATH options.
RUN (Default)
NORUN
Enables and disables a unit’s availibility to the host. When RUN (default) is
specified, the devices that make up the unit will be spun up and the unit will be
made available to the host. If NORUN is specified, the devices that make up the
unit will still be spun up, but the unit will not be made available to the host.
WRITE_PROTECT
NOWRITE_PROTECT (Default)
Enables and disables write protection of the unit.
Note
Writes may still be performed to a write-protected RAIDset to satisfy a
reconstruct pass or to reconstruct a newly replaced member. However,
write protect will disable the writing of any new data.
WRITEBACK_CACHE
NOWRITEBACK_CACHE (Default)
Enables and disables the controller’s write-back cache on this unit.
Note
It may take up to 5 minutes to flush unwritten data from the write-back
cache once you disable write-back caching.
Qualifiers for a Unit Created from a Stripeset
MAXIMUM_CACHED_TRANSFER=
n
MAXIMUM_CACHED_TRANSFER=32 (Default)
Specifies the maximum size transfer in blocks to be cached by the controller. Any
transfers over this size are not cached. Valid values are 1–1024.
PREFERRED_PATH=THIS_CONTROLLER
PREFERRED_PATH=OTHER_CONTROLLER
NOPREFERRED_PATH (Default)
Note
The PREFERRED_PATH and NOPREFERRED_PATH qualifiers are
valid for HSJ and HSD controllers only. The preferred path for HSZ
controllers is determined by the unit number (the target portion of the
unit number–the hundreds place) specified on the ADD UNIT command.
Command Line Interpreter B–23