User`s guide

SHUTDOWN OTHER_CONTROLLER
If the OVERRIDE_ONLINE qualifier is specified, the controller shuts down after
all customer data is written to disk.
CAUTION
Customer data may be lost or corrupted if the OVERRIDE_ONLINE
qualifier is specified.
Qualifiers for HSZ Controllers
IGNORE_ERRORS
NOIGNORE_ERRORS (Default)
If errors result when trying to write user data, the controller is not shut down
unless IGNORE_ERROR is specified.
If the IGNORE_ERRORS qualifier is specified, the controller shuts down even if
all customer data cannot be written to disk from the write-back cache.
CAUTION
Customer data may be lost or corrupted if the IGNORE_ERRORS
qualifier is specified.
IMMEDIATE_SHUTDOWN
NOIMMEDIATE_SHUTDOWN (Default)
If IMMEDIATE is specified, the controller shuts down immediately without
checking for online devices or flushing user data from write-back cache to disk.
CAUTION
Customer data may be lost or corrupted if the IMMEDIATE qualifier is
specified.
Examples
1.
CLI> SHUTDOWN OTHER_CONTROLLER
Shuts down the other controller as long as the other controller does not have
any units online.
2.
CLI> SHUTDOWN OTHER_CONTROLLER OVERRIDE_ONLINE
Shuts down the other controller even if there are units online to the other
controller.
B–126 Command Line Interpreter