User`s guide
Error 9170: <device type> <device name> at PTL <port> <target> <lun> No
device installed
Explanation: When a unit is added or initialized, the configuration of the
devices that makes up the unit is checked. If no device is found at the PTL
specified, this error is displayed.
Check both the logical and physical configuration of the unit and correct any
mismatches.
Error 9180: <device type> <device name> at PTL <port> <target> <lun> Incorrect
device type installed
Explanation: When a unit is added or initialized, the configuration of the
devices that make up the unit is checked. If a non disk device is found at the
PTL specified, this error is displayed.
Check both the logical and physical configuration of the unit and correct any
mismatches.
Error 9190: Unit <unum> is currently online
Explanation: When a SHUTDOWN, RESTART, or SELFTEST command is
entered without the OVERRIDE_ONLINE qualifier and online devices are
found, the command is aborted and the units currently online are listed.
Either retry the command with OVERRIDE_ONLINE qualifier or dismount
all devices from the hosts.
Error 9200: <name> conflicts with unit names
Explanation: This error results from an ADD command. Names in the
format of Dn and Tn, when n is a number from 0 to 4094, are reserved for
units. Rename the storageset or device that is being added so it does not
conflict with the unit names and retry the command.
Error 9210: Cannot check if drives are online to the other controller
Explanation: When trying to check for online drives on the other controller,
there was a communication failure.
Retry the command.
Error 9220: You cannot specify NOREAD_CACHE while in WRITEBACK_
CACHE mode
Explanation: WRITEBACK_CACHE is specified for this unit. READ_
CACHE cannot be specified while WRITEBACK_CACAHE is set.
Reissue the SET command disabling both WRITEBACK_CACHE and READ_
CACHE.
Error 9230: Unable to modify switches requested
Explanation: This error results from a SET command. The system is
currently busy.
Retry the SET command later.
Command Line Interpreter B–147