User`s guide

Figure 3–4 SW500-Series Cabinet Loading Sequence
CXO-3902B-MC
MOUNTING
LOCATIONS
MOUNTING
LOCATIONS
STORAGE
POSITION S9
STORAGE
POSITION S8
CONTROLLER
POSITION C2
STORAGE
POSITION S7
STORAGE
POSITION S6
CABINET FRONT
CABINET REAR
HOLE
#20
HOLE
#26
HOLE
#32
HOLE
#14
HOLE
#10
STORAGE
POSITION S5
STORAGE
POSITION S4
STORAGE
POSITION S3
CONTROLLER
POSITION C1
STORAGE
POSITION S1
STORAGE
POSITION S2
HOLE
#2
HOLE
#20
HOLE
#26
HOLE
#32
HOLE
#14
HOLE
#8
FRONT-TO-REAR
SCSI-2 CABLE
ROUTING POINTS
HOLE
#7
CDU A
CDU B
INTERNAL
CI CABLE
ROUTING
POINT
CI BULKHEAD
Use of a second controller shelf: By convention, the first controller shelf (C1)
would use S1-S5; the second controller shelf (C2) would use S6, S8, and S9.
This permits two subsystems, one with up to 24-28 3½-inch SBB devices (in
the front), and the other with 18-21 3½-inch SBB devices (in the rear).
SW300-series cabinet shelves: The SW500-series cabinets do not accept
SW300-series cabinet integrated controller/storage shelves.
Refer to the StorageWorks SW500-Series Cabinet Installation and Users Guide
for more details.
Figure 3–5 shows the loading sequence for storage and controller shelves when
TZ8xx-series tape devices are installed in an SW500-series cabinet. Refer to
the StorageWorks SW500-Series Cabinet Installation and Users Guide for new
loading sequence illustrations for cabinets using 4 GB or larger disk drives.
Configuration Rules and Restrictions 3–7