Technical data

Extended Error Format:
This extended error message is returned by the DZ read LPR test or if a
character comparison error occurs in the other DZ tests. The second field
(4-digit field) is the extended error format.
001 000a ssssssss cccccccc lprlprlp llllllll rrrrrrrr eeeeeeee
Where:
ssssssss - is the suberror code
cccccccc - is the value of the DZ CSR
lprlprlp - is the contents of the line parameter register
llllllll - is the line number
rrrrrrrr - is the data read back
eeeeeeee - is the expected data
The extended error code returned by polled and interrupt test when a transfer
times out is in the following format:
001 000b ssssssss cccccccc lprlprlp llllllll xxxxxxxx tttttttt
Where:
ssssssss - is the suberror code
cccccccc - is the value of the DZ CSR
lprlprlp - is the contents of the line parameter register
llllllll - is the line number
xxxxxxxx - is the number of characters transmitted
tttttttt - is the value of the DZ transmit control register
The suberror codes reported by the DZ self-test are as follows:
Interpreting Error Codes A–7