Technical data

command to view the extended error information in hexadecimal. The extended
error codes can be of several types as shown in the following examples.
Extended Error Format 0001:
This format is used by the synchronous communication option RAM test.
0020 0001 aaaa0000 00000000 00000000 00000000 bbbb0000 ccccdddd eeeeffff
Code Meaning
0014 FRU code for the DSW21 synchronous communication option
0001 Format type for the RAM test
aaaa Test status
bbbb Data size (1=byte access, 2=word access, 4=long access)
cccc Address low
dddd Address high
eeee Actual data
ffff Expected data
Extended Error Formats 0002 through 0006 are used by the DSW21
synchronous communication self-tests.
Extended Error Format 0002:
0020 0002 aaaabbbb ccddeeff gghhiijj kkkkllll mmmmnnnn oooopppp qqqqrrrr
Extended Error Format 0003:
0020 0003 aaaabbbb ccddeeff gghhiijj kkkkllll mmmmnnnn oooopppp qqqqrrrr
Extended Error Format 0004:
0020 0004 aaaabbbb ccddeeff gghhiijj kkkkllll mmmmnnnn oooopppp qqqqrrrr
Extended Error Format 0005:
0020 0005 aaaabbbb ccddeeff gghhiijj kkkkllll mmmmnnnn oooopppp qqqqrrrr
Extended Error Format 0006:
0020 0006 aaaabbbb ccddeeff gghhiijj kkkkllll mmmmnnnn oooopppp qqqqrrrr
Interpreting Error Codes A–39