Technical data

next field is the extended error format, one of the eight formats listed in the
following examples.
Extended Error Format 0001:
This format is used by the graphics register test, FIFO test, video test, and the
virtual test.
xxx 0001 aaaaaaaa bbbbbbbb cccccccc dddddddd
Code Meaning
xxx FRU
aaaaaaaa Error code
bbbbbbbb Address of the register or location being accessed
cccccccc Expected data or data written
dddddddd Actual data or data read
Extended Error Format 000B:
This format is used by the graphics FIFO test.
001 000B aaaaaaaa bbbbbbbb cccccccc dddddddd eeeeeeee
Code Meaning
001 FRU
aaaaaaaa Error code
bbbbbbbb FIFO control flag being tested
cccccccc Address of the register
dddddddd Expected register content
eeeeeeee Register content
Interpreting Error Codes A–59