Technical data

A.2.31 Network Interconnect (NI) System Test Error Codes (Model 60
Only)
The following example and table explain and list Model 60 NI system test error
messages.
?? 9 NI 000X 00YY 0 00:00:00.00
In the example, X is the source of the error:
1 - Test
2 - System test monitor
3 - Device driver
4 - VAXELN
5 - System
YY indicates the specific error code (shown in Table A–32).
Table A–32 NI System Test Error Codes (Model 60 Only)
Error Source (X) Error Code (YY) Meaning
1 02 Initialization failed
1 04 LANCE underflow reported
1 06 DMA transmit failed
1 08 Unknown transmit error
1 0A Receive failed
1 12 DMA receive failed
1 14 Unknown receive error
1 16 Data compare error
2 02 WST$INIT failed
4 02 Bad memory allocation
4 04 Create device failed
4 06 Create area failed
5 02 Unknown transmit error
5 04 Bad transmit status
5 06 Transmit own bit says LANCE
(continued on next page)
A–80 Interpreting Error Codes