Technical data

2.8.13 TURBOchannel Adapter Self-Test (T 13) (Model 60 Only)
Restriction
The system power-up self-test run time restricts the self-test’s ability to call
the emulator to run power-up self-tests on the option firmware.
To Initialize the TURBOchannel and Option
Arbitrary TURBOchannel resets are not performed. The following explains the
process to initialize the TURBOchannel and option:
If you halt VMS and want to run the emulator, but do not want to maintain
the state of the TURBOchannel or the option, enter the UNJAM command
at the console prompt. This initializes both the TURBOchannel and the
option.
Table 2–15 lists the tests that are included in the power-up TURBOchannel
Adapter (TCA) self-test. The power-up self-test is automatically invoked during
the initial power-up of the VAXstation 4000 hardware and it tests the TCA in a
sequential manner.
Table 2–15 TURBOchannel Adapter Self-Test (13)
Self-Test Function
TCA register
test
Tests the following functions of the CSR:
RESET (toggles and checks bit in CSR)
TURBOchannel timeout (reads the TURBOchannel while
holding RESET)
FIFO (empties bit set and clears by writing and reading FIFO)
INV (does an invalid map DMA)
TCA interrupt
test
Generates an interrupt.
Tests to see if the Interrupt Service Routine (ISR) can be reached
and then turns off interrupts and ensures that the ISR is not
reached.
(continued on next page)
2–22 Diagnostic Testing