Technical data

Important Notes About the System Test
The following are important notes about the system test:
The system test runs under a modified VAXELN kernel which is
loaded from ROM.
The system test causes a worst-case environment in terms of
system interaction, using maximum DMA and interrupts.
2.10 System Test Monitor (Model 60 Only)
This section describes the Model 60 test command interface that you use to
run the system test on a device or on the whole system. Table 2–16 shows the
general format for running the system test using the test command.
Table 2–16 Running the System Test Using the Test Command
Command Action
T 100 Runs system test in the customer environment for two
passes.
T 101 Runs system test in the Digital Services environment for
two passes.
T 102 Runs system test in the Digital Services environment. Press
Ctrl C
to exit.
T 103 Runs system test in the manufacturing environment. Press
Ctrl C
to exit.
T 106 Runs system test for specific devices. System prompts for
specific device. 1=Yes, 0=No.
This test runs the system test in the manufacturing environment. This test writes over data on
hard disks. Do not use on customer systems; it erases customer data. Press
Ctrl C
to exit.
Note
Make sure that loopback connectors are installed while the system is in
the Digital Services environment. SET DIAGENV 2 to run in Digital
Services environment. (Table 3–2 and Table 2–2 contain descriptions
and commands for the diagnostic environments.)
2–24 Diagnostic Testing