Technical data

Example 2–8 shows the DSW21 synchronous communication system test
summary.
Example 2–8 Communication System Test Summary
COMM Test Summary Screen..........................................
------------------------------------------------------------------
SCC1 Tx: 36 Rx: 36 Err: 0 INT-NOCABLE
SCC2 Tx: 36 Rx: 36 Err: 0 EXT-H3199
SCC3 Tx: 36 Rx: 36 Err: 0 INT-NOCABLE
Status Block:
-------------
FRU: 14 FTY: 6
CSR: 30 STA: 1
HWV: 2 SWV: 5
CC1: F CC2: 0
MOD: 1 CNT: 1
CHN: 2 SEL: 2
PROT: 3 SCM: 9CF
2.12 Utilities
The TEST commands run or display available utilities. Utilities can be run
with all parameters input either at the command line or at the utilities prompt
for additional input.
2.12.1 Utility Groups
The console firmware provides four utility groups which are described in the
following table:
Utility Group Command Procedure Functions
Graphics T/UT 2 Provides colored screens and
geometric patterns
NI SET MOP 1
SET TRIGGER 1
SET PSE 1
SET PSWD
Enables MOP - NI listener
Enables trigger - entity-based module
Enables console password
Allows user to set console password
SCSI T/UT 10 Key utilities, floppy formatter, and
disk eraser
TCA T/UT TCA Invokes the MIPS/REX TURBOchannel
emulator
Diagnostic Testing 2–33