Technical data

3.1.2.4 CONFIG
The CONFIG parameter is used to display the system configuration and device
status.
The SET command does not apply to this parameter.
Use SHOW DEVICE for more information on SCSI devices.
Refer to Section 2.3.2 for an example of a configuration display.
3.1.2.5 DEVICE
The DEVICE parameter is used to display SCSI and Ethernet device
information.
The SET command does not apply to this parameter.
Refer to Section 2.3.1 for information displayed by the SHOW DEVICE
command.
3.1.2.6 DIAGENV
The DIAGENV parameter determines the diagnostic environment that the
diagnostics run under. Table 3–2 lists the diagnostic environments and their
use.
Table 3–2 Diagnostic Environments
Environment Usage
Customer No setup is required.
Default environment on power-up.
Digital Services Provides a more thorough test than in customer environment.
Some tests require loopback connectors for successful completion.
Manufacturing Some tests require loopback connectors for successful completion.
Do not use this environment in the field. It can erase
customer data.
Loop on error
Digital Services
The system loops on a test when an error occurs.
Loop on error
manufacturing
The system loops on a test when an error occurs. Do not use
this environment in the field. It can erase customer data.
Using the Console 3–5