Technical data

To set the diagnostic environment, enter a console command from Table 3–3.
Table 3–3 SET DIAGENV Command
Command Result
SET DIAGENV 1
Sets environment to customer environment
SET DIAGENV 2
Sets environment to Digital Services environment
SET DIAGENV 3
Sets environment to manufacturing environment
SET DIAGENV 80000001
Sets environment to loop on error in Digital
Services environment
SET DIAGENV 80000002
Sets environment to loop on error in manufacturing
environment
The following is an example of the SET DIAGENV and SHOW DIAGENV
commands:
Command Result
SET DIAGENV 2 DIAGENV = 2
SHOW DIAGENV DIAGENV = 2
3.1.2.7 ERROR
The ERROR parameter displays extended error information about errors that
that occur during the last execution of the following tests:
Initialization (power-up) test
Extended self-test
System test
The SET command does not apply.
Refer to Section 2.4 and Section A.1 for additional information about immediate
and extended error messages.
The following is an example of the SHOW ERROR command:
Command Result
SHOW ERROR ?? 150 10 SCSI 0032
150 000E 00000005 001D001D 03200000 00000024
(cont.) 00000002 00000000 00000004
3–6 Using the Console