Technical data

How to Log In
Follow these procedures to log in:
Step Procedure
1 Set PSE to 1.
2 Enter the LOGIN command at the >>> prompt.
3 Enter the password at the PSWD0>>> prompt.
The password must be exactly 16 characters.
Valid password characters are 0 through 9 and A through F.
3.1.2.16 SCSI
The SCSI parameter sets the SCSI ID for the system SCSI controller.
The system SCSI ID default is set to 6.
The following is an example of the SHOW SCSI and SET SCSI commands:
Command Result
SHOW SCSI SCSI = 6
SET SCSI 7 SCSI = 7
3.1.2.17 TRIGGER
The TRIGGER parameter enables the entity-based module (EBM).
If both the TRIGGER and MOP parameters are equal to 1, then the EBM and
the NI listener is enabled. You can then access the console or boot the system
from a remote system.
The following is an example of the SET TRIGGER and SHOW TRIGGER
commands:
Command Result
SHOW TRIGGER TRIGGER = 0
SET TRIGGER 1 TRIGGER = 1
Using the Console 3–11