User manual
PRESET NAME -> change the name
of preset selected by preset number.
Name is up to 12 letters.
SAVE -> save changed name
CANCEL -> return to main menu
Preset Save: Cre
ate-> Input-> Select#-> Output-> Select Multiple ##->If you add more input go to Input again->
If you done all Input and Output ->Enter-> Preset Save->
Preset Number -> Select#-> Preset Name-> Input Name->Save
Preset Call: Preset Call->
Select Preset Name-> Preset Call
3-2 Product number setting
• Product ID setting (DIP switch)
• It sets its own address of matrix if many matrixes are used.
• It sets in binary values.
mber is the value set in deep switches of the equ
• ipment and can be set in the values of 1 ~
,
OFF, 5 ON, 6 OFF, 7 OFF, 8 OFF
The product nu
255. If the value is set as “0”, then the channel does not work.
For example;
F, Product ID = 01 (00000001b) -- 1 ON, 2 OFF, 3 OFF, 4 OFF, 5 OFF, 6 OFF, 7 OFF, 8 OF
Produ
ct ID = 10 (00001010b) -- 1 OFF, 2 ON, 3 OFF, 4 ON, 5 OFF, 6 OFF, 7 OFF, 8 OFF
Product ID = 23 (00010111b) -- 1 ON, 2 ON, 3 ON, 4
**The product ID is set number “1” at the time of its delivery (Factory Default).
3-3
settings as follows:
l.
•
You may set port COM 1 ~ 4 or you may use all available ports.
D0 D1 D2 D3 D4 D5 D6 D7
LSB MSB
RS-232C (COM PORT) communication setting
After booting the matrix, connect RS-232C cable and then make communication
• Execute DVI switch controller 3.0, MiniTerm.exe or hyper termina
Communication setting:
Copyright 2008 RTcom USA., Inc.
17