User`s manual

47
6.3 Alarm Settings
6.3.1 Alarm Input Settings
User can define the alarm behaviors and the corresponding actions for triggered alarm.
Alarm input: Select the alarm input number from 1 to 4, the corresponding settings
will show in the window.
Enabled: Select On to enable the alarm.
Alarm name : Input the name for the alarm.
Alarm type : Select the alarm trigger type.
N.O. Normal open contact, N.C Normal Close contact
Trigger Duration : Select the trigger type and time duration
Timeout The alarm will last for the set time duration.
Transparent The alarm output remains active until the triggered event ends.
Non-Stop The alarm will be continuously active until user presses “ACK” key.
Alarm Handle : To configure the system monitor and alert behavior when the
alarm is triggered. The settings include buzzer, spot option, trigger alarm out, send
Email, send alarm notification.
Triggered Camera : The system allows user to trigger multiple cameras for event
recording, select the cameras that would like to be triggered when alarm is
detected.
Click Apply to save the settings.