User's Manual

Digital Monitoring Products XT30/XT50 Installation Guide
18
ComPlIanCe
False Alarm Reduction Programmable Options ANSI/SIA CP-01-2007
24.1 Shipping Defaults and Recommended Programming
SIA CP-01 FEATURE
PARAGRAPH # AND
DESCRIPTION
DMP PROGRAMMING
GUIDE LT-0981
SECTION #
REQUIREMENT RANGE
SHIPPING
DEFAULT
RECOMMENDED
PROGRAMMING*
4.2.2.1ExitTime 8.6ExitDelay
Required
(Programmable)
45sec.-250sec.
60
Seconds
60Seconds
4.2.2.2Progress
Annunciation
13.14Prewarn
Address
Allowed
Individualkeypads
may be disabled per
zone
All
keypads
enabled
Allkeypadsenabled
4.2.2.3ExitTime
Restart
8.6ExitDelay RequiredOption
For re-entry during
exit time
Enabled Enabled
4.2.2.5AutoStayArm
onUnvacatedPremises
8.17Occupied
Premise - SeeInstall
Guide
RequiredOption
(exceptfor
remotearming)
OccupiedPremise
NO/YESoption
Enabled
EnabledYes
for Residential
Applications
4.2.4.4ExitTimeand
Progress Annunciation/
Disable - for Remote
Arm
NotAvailableon
Remote Arming
AllowedOption
Progress Annunciation
Always disabled for
Remote Arming
Not
Available
Remote Arming not
allowed for CP-01
installations.
4.2.3.1EntryDelay(s) 8.5EntryDelay
Required
(Programmable)
30sec.–240Sec.**
30
Seconds
Atleast30Seconds**
4.2.5.1AbortWindow–
forNon-FireZones
3.3TransmitDelay RequiredOption
Disablebyzoneor
zonetype
Enabled
NTDY
EXZone
Enabled
4.2.5.1AbortWindow
Time–forNon-Fire
Zones
3.3TransmitDelay
Required
(Programmable)
20sec.,30sec.,or
40sec.**
30
Seconds
Atleast20Seconds**
4.2.5.1.2Abort
Annunciation
3.3TransmitDelay RequiredOption
Annunciate that
no alarm was
transmitted
Yes Yes
4.2.5.4.1Cancel
Annunciation
AlwaysEnabled-Not
Programmable
RequiredOption
Annunciate that
a Cancel was
transmitted(S49)
Always
Enabled
Yes
4.2.6.1&4.2.6.2
Duress Feature
UserCode+1=
AmbushCodeNot
Available
AllowedOption
No1+derivativeof
another user code/no
duplicates with other
user codes
Code+1
Always
Disabled
NotProgrammable
4.3.1CrossZoning 13.16CrossZone RequiredOption
Yes/NoZone
Programming
No
Enabledusingtwoor
more programmed
zones
4.3.1Programmable
Cross Zoning Time
8.7CrossZoneTime Allowed 4sec.-250sec. 0Seconds
Perwalkpathin
protected premises
4.3.2SwingerShutdown
NotAvailable—
AlwaysOn
Required
Forallnon-re
zones,shutdown
after 1 trip
Always
On
AlwaysOn
4.3.2SwingerShutdown
Disable
13.13SwingerBypass Allowed
For non-police
responsezones
Yes Enabled(allzones)
4.3.3FireAlarm
Verication
13.5ZoneType RequiredOption FV Type Zone No
Yes as required
(unlesssensorscan
selfverify)
4.5CallWaitingCancel
3.17FirstTelephone
Number
RequiredOption
Include*70Pin
TelephoneNumber
Disabled
Enabledifuserhas
call waiting
*ProgrammingatinstallationmaybesubordinatetootherNRTLrequirementsfortheintendedapplication.
**ForNRTLInstallations,combinedEntryDelayandTransmitDelayshouldnotexceed1minute.