Installation Guide

2 1100DH SERIES INSTALLATION GUIDE | DIGITAL MONITORING PRODUCTS
ADDITIONAL INFORMATION
Black
Green
Yellow
Red
J4
RED
PRO
J8
XT30/XT50 Series Panel
J7
RJ SUP
AC
1
2
3
4 5 6 7
8
10
11 12
9
+B
BELL
GND
SMK
RED
YEL
GRN
BLK
AC
-B
1100DH
Receiver
PANEL
Can be extended from
the panel up to 500 ft
using 22 AWG or 1,000
ft using 18 AWG
Figure 2: Wiring the 1100DH to the Panel
Mounting Holes
3
The panel immediately recognizes the 1100DH if the panel is programmed with a house code. Do not use
shielded wire between the panel and receiver.
1. Connect the red, yellow, green, and black wires to the PANEL terminal on the 1100DH.
2. Connect the other end of the wires to the terminals 7, 8, 9, and 10 on the panel. See Figure 2
3. Use the included #6 screws to secure the 1100DH to the surface. See Figure 2 for mounting hole
locations.
4. Snap the cover back on to the base.
WIRE AND MOUNT THE RECEIVER
Table 1: Zone Number Designations
DMP PANEL AVAILABLE ZONES ZONE RANGES
XT50 with built-in receiver 48 11 - 14, 21 - 24, 31 - 34, 41 - 44, 51 - 54, 61 - 64, 71 - 74, 81 - 84, 80, 85 - 99
XT30 and XT50 (1100D Series) 32 11 - 14, 21 - 24, 31 - 34, 41 - 44, 51 - 54, 61 - 64, 71 - 74, 81 - 84
Wiring Specifications for Keypad Bus
1. DMP recommends using 18 or 22-gauge unshielded wire for all keypad and LX-Bus circuits. Do Not use twisted pair
or shielded wire for LX-Bus and Keypad Bus data circuits. To maintain auxiliary power integrity when using 22-gauge
wire do not exceed 500 feet. When using 18-gauge wire do not exceed 1,000 feet. Install an additional power supply
to increase the wire length or add devices.
2. Maximum distance for any one circuit (length of wire) is 2,500 feet regardless of the wire gauge. This distance can
be in the form of one long wire run or multiple branches with all wiring totaling no more than 2,500 feet. As wire
distance from the panel increases, DC voltage on the wire decreases.
3. Maximum number of devices per 2,500 feet circuit is 40.
4. Maximum voltage drop between the panel (or auxiliary power supply) and any device is 2.0VDC. If the voltage at
any device is less than the required level, add an auxiliary power supply at the end of the circuit. When voltage is
too low, the devices cannot operate properly. Refer to the panel installation guide and LX-Bus/Keypad Bus Wiring
Application Note (LT-2031).
Programming Zones
Refer to the panel XT30/XT50 Series Programming Guide (LT-0981) for complete wireless programming information.
When any wireless input zone for a particular address is programmed, the 1100DH responds to the panel for this address.
Other devices, such as keypads or hardwired zone expanders, cannot use this address. Zones connected directly to the
panel cannot be wireless. See Table 1 for designated zone numbers.