4.1 Mounting the Enclosure
TheenclosurefortheXTLpanelmustbemountedusingtheprovided#6screwsinthefourmountingholes
showninFigure2.Mounttheenclosureinasecure,dryplacetoprotectthepanelfromdamagedueto
tampering or the elements. It is not necessary to remove the PCB when installing the enclosure.
65555
RESET
S1
LOAD
S2
BAT
J1
PROG
RED
PWR
MODEL XTL
Mounting Hole
Locations
TX RF RX
Figure 2: Mounting Hole Locations
Primary Power Supply
5.1 DC Input
MounttheXTLpanelnearawalloutletfortheModel372-500plug-inDCpowersupply.Inadditionto
poweringthepanel,theDCplug-inpowersupplyalsochargestheback-upbattery.The372-500mustbe
locatedwithin100feetofthepanelusing22AWGwireor250feetusing18AWGwire.Usethefollowing
steps to connect the plug-in power supply:
1.Using18or22AWGwire,connectthepanelPWR(J2)rstterminal(+)tothepositiveterminalon
the power supply.
2.ConnectthepanelPWR(J2)secondterminal(-)tothenegativeterminalonthepowersupply.
3.Plugthepowersupplyintoa110VoltACdedicatedoutletnotcontrolledbyaswitch.
65555
RESET
S1
LOAD
S2
BAT
J1
PROG
RED
PWR
MODEL XTL
Wire Exits for DC
Power Supply
+
-
TX RF RX
Model 372-500
DC Plug-in
Power
Supply
Use 18 AWG or 22 AWG for
Power Supply connection
+
_
Figure 3: DC Power Supply Connection