User's Manual
1105 Installation Guide Digital Monitoring Products
3
1105 External Contact Mounting
Whenconnectinganexternalcontacttotheterminalblock,DMPrecommendsusing18or22-gaugeunshieldedwire.
Do notusetwistedpairorshieldedwire.Connect the external contact as normally open (N/O) or normally closed
(N/C)withoutanyend-of-lineresistor.RefertotheContactoptionunderZoneInformationintheappropriate panel
programming guide.
Note: When using both the internal reed switch and external terminal block, you must use consecutive zone
numbers. Refer to the following examples:
• XR500 system—zones562and563orzones893and894
• XR100 system—zones523and524orzones593and594
• XT30/XT50 Series—zones31and32orzones34and41
Figure 7: External Contact Wiring
Magnet
1105 Universal
Transmitter
External
Contact
External Contact
Terminal Block
Internal Contact
Reed Switch
Internal Contact Magnet
External Contact
Program External
Contact as next
consecutive Zone
Program
Internal
Contact
as one Zone
Window
Door
1105-EOL Wiring and Connecting Contacts
Whenconnectinganexternalcontacttotheterminalblock,DMPrecommendsusing18or22-gaugeunshieldedwire.
Do notusetwistedpairorshieldedwire.Connectthecontactasnormallyopen(N/O)ornormallyclosed(N/C)withthe
470Kend-of-lineresistorasshowninFigure8.
Note: The Normally Open YES NO option in the panel wireless zone programming has no affect on the transmitter
operationwhenusingthe470Kend-of-lineresistor.
Installing or Replacing the Battery
Observepolaritywheninstallingthebattery.Useonly3.0Vlithiumbatteries,DMPModelCR123,ortheequivalent
batteryfromalocalretailoutlet.ForULinstallations,onlyuse#123batteriesmanufacturedbyEnergizerforthe
1105orCR123AbatteriesmanufacturedbyPanasonicforthe1105-EOL.
Note: When setting up a wireless system, it is recommended to program zones and connect the receiver before
installing batteries in the transmitters.
1. If installed, remove the transmitter housing cover as shown in Figure 1.
2.Ifreplacingthebattery,removetheoldbatteryanddisposeofitproperly.
3.Placethe3.0VlithiumbatteryintheholderasshowninFigure2andpressintoplace.
4.Alignthebackofthetransmittercovernexttothebatteryandsnapthecoverintoplace.
Caution:Riskofre,explosion,andburns.Donotrecharge,disassemble,heatabove212°F(100°C),or
incinerate. Properly dispose of unused batteries.
External Contact
Program Contact in
Panel Zone Programming
Contact
Terminal
Block
470K
470K
Series for N/C
Parallel for N/O
Figure 8: Contact Terminal Block Wiring