User's Manual
Table Of Contents
- Panel Specifications
- Introduction
- System Components
- Installation
- Primary Power Supply
- Secondary Power Supply
- Bell Output
- Keypad Data Bus
- Smoke and Glassbreak Detector Output
- Burglary Zones
- Powered Zone for 2-Wire Smoke Detectors
- Annunciator Outputs
- Telephone RJ Connector
- Ethernet Connector J1
- Reset Header J16
- Flash Load Jumper J18
- Cellular Connections
- On-Board 1100 Series Wireless Antenna Connection
- Wireless Keypads
- Listed Compliance Specifications
- Household Burglar-Alarm System Units ANSI/UL 1023
- Digital Burglar Alarm Communicator System Units ANSI/UL 1635
- Central Station Burglar Alarm Units ANSI/UL 1610
- Household Fire Warning System ANSI/UL 985 NFPA 72 Specifications
- California State Fire Marshal Specifications
- False Alarm Reduction Programmable Options ANSI/SIA CP-01-2010
- Troubleshooting
- Wiring Diagrams
- Revisions to This Document
Digital Monitoring Products XT30/XT50 Installation Guide
12
InstallatIon
10.3 Zone Response Time
Aconditionmustbepresentonazonefor500millisecondsbeforeitisdetectedbythepanel.Ensure
detectiondevicesusedontheprotectionzonesareratedforusewiththisdelay.
10.4 Keyswitch Arming Zone
YoucanuseamomentarykeyswitchonazoneprogrammedasanArmingtypeforuseinarmingand
disarming the system without a code.
Powered Zone for 2-Wire Smoke Detectors
11.1 Terminals 25 and 26
Aresettable2-wireClassBpoweredzoneisprovidedonterminals25(positive)and26(negative)ofthe
panel.Forprogrammingpurposes,thezonenumberis10ontheXT30/XT50.ThezoneusesaModel309,3.3k
OhmEOLresistor(providedwiththepanel)andhasanoperatingrangeof8.8to13.9VDC.
Thecompatibilityidentieris:B
Caution:Sensorresetonzone10dropspowertodevicesonthiszone,causingthepaneltosenseanopen
conditiononallzonetypesotherthanFire,FireVerify,andSupervisory.Whenevernon-Fireandnon-
Supervisoryzonetypesareusedonzone10,maketheappropriateadjustmentstothezone’sArmedAction
to prevent false alarms from occurring.
Manufacturer Model
Detector
ID
# of
Detectors
Zone Expansion Modules
DMP/Hochiki SLR-835B HD-6 7 715, 715-8, 715-16, 725
Sentrol/ESL 429AT, 521B, 521BXT S09A 12 715, 715-8, 715-16
System Sensor 2WTA-B, 2WTR-B A 10 715, 715-8, 715-16
Annunciator Outputs
12.1 Description
Thefourannunciatoroutputscanbeprogrammedtoindicatetheactivityofthepanel’szonesorconditions
occurring on the system. Annunciator outputs do not provide a voltage but instead switch-to-ground voltage
from another source. The outputs can respond to any of the conditions listed below:
1) Activationbyzonecondition:Steady,Pulse,Momentary,orFollower 6) Ambushalarm
2) Manuallyfromthekeypad 7) ExitandEntrytimers
3) Communicationfailure 8) SystemReady
4) Armedareaannunciation 9) LatetoClose
5) FireAlarmorFireTrouble
12.2 Harness Wiring
TheopencollectoroutputsareaccessiblebyinstallingtheDMP300Harnessonthe4-pinheaderlabeledJ11.
The output locations are shown below. For listed applications, devices connected to outputs must be located
within the same room as the panel.
Output Color Wire Output Color Wire
1 Red 1 3 Green 3
2 Yellow 2 4 Black 4
12.3 Model 860 Relay Module
ConnectaModel860RelayModuletothepaneltoproviderelaysfortheannunciatoroutputsthatcanbe
used for electrical isolation between the alarm panel and other systems or for switching voltage to control
variousfunctions.Themoduleincludesonerelayandprovidesthreeadditionalsocketsforexpansionofup
tofourrelays.Powerissuppliedtotherelaycoilsfromthepanelkeypadbus.The860mountsinsidethe
panelenclosureusingthe3-holemountingconguration.Plasticstandoffsareprovidedwiththemodulefor
easeofinstallation.A4-wireharnessisalsoprovidedthatconnectstheModel860tothepanel.
Relay Contact Rating: 1Ampat30VDC