User's Manual
Table Of Contents
- Panel Specifications
- Introduction
- System Components
- Installation
- Primary Power Supply
- Secondary Power Supply
- Bell Output
- Keypad Data Bus
- Smoke and Glassbreak Detector Output
- Burglary Zones
- Powered Zone for 2-Wire Smoke Detectors
- Annunciator Outputs
- Telephone RJ Connector
- Ethernet Connector J1
- Reset Header J16
- Flash Load Jumper J18
- Cellular Connections
- On-Board 1100 Series Wireless Antenna Connection
- Wireless Keypads
- Listed Compliance Specifications
- Household Burglar-Alarm System Units ANSI/UL 1023
- Digital Burglar Alarm Communicator System Units ANSI/UL 1635
- Central Station Burglar Alarm Units ANSI/UL 1610
- Household Fire Warning System ANSI/UL 985 NFPA 72 Specifications
- California State Fire Marshal Specifications
- False Alarm Reduction Programmable Options ANSI/SIA CP-01-2010
- Troubleshooting
- Wiring Diagrams
- Revisions to This Document
XT30/XT50 Installation Guide Digital Monitoring Products
13
InstallatIon
Telephone RJ Connector
13.1 Description
ConnectthepaneltothepublictelephonenetworkbyinstallingaDMP356RJCablebetweenthepanel’sJ3
connectorandtheRJ31XorRJ38Xphonejack.CAUTION-Toreducetheriskofre,useonlyNo.26AWGor
largertelecommunicationlinecord,suchasDMPModel356SeriesPhoneCords.
AtwopinheaderlabeledRJSUP(J7)isprovidedtoallowmonitoringofthetelephonecableconnected
betweenthepanelandaRJ38Xjack(pins2and7jumpered).AttachaDMPModel306HarnessbetweenJ7
andanyavailablezone.TheJ7pinsareconnectedviathetelephonecabletotheRJ38Xjackpins2and7.
TheRJ38Xjackprovidesajumperbetweenpins2and7whichcompletesthecircuit.Programthezoneasa
Supervisorytype(SV).Whenthetelephonecableisremoved,thekeypaddisplayszonetroubleandproduces
a steady tone.
To Telephone
Line
RJ31X or RJ38X
Phone Block
8
7
6
54
3
2
1
Ring Tip
To Premise
Phone(s)
Ring 1
Tip 1
Figure 7: Phone Jack Wiring
13.2 FCC Registration
The panel complies with FCC part 68 and is registered with the FCC.
Registrationnumber:CCKAL00BXT50
RingerEquivalence:0.0B
13.3 Notication
Registered terminal equipment must not be repaired by the user. In case of trouble, the device must be
immediatelyunpluggedfromthetelephonejack.Thefactorywarrantyprovidesforrepairs.Registered
terminalequipmentmaynotbeusedonpartylinesorinconnectionwithcointelephones.Noticationmust
be given to the telephone company with the following information:
a.Theparticularline(s)theserviceisconnectedto
b. The FCC registration number
c. The ringer equivalence
d.Themake,model,andserialnumberofthedevice
Ethernet Connector J1
14.1 Description
TheEthernetConnector(J1)isavailableontheNetworkversionandconnectsdirectlytoanEthernet
networkusingastandardpatchcable.
14.2 Ethernet LEDs
ThetwoLEDs,locatedontheleftsideoftheJ1EthernetConnector,indicatenetworkoperation.Thetop,
LinkLEDisasteadygreenlightwhenanethernetcableisconnected.Thebottom,ActivityLEDashes
yellow to indicate messages are being received or transmitted.