User's Manual
Table Of Contents
- Panel Specifications
- Introduction
- System Components
- Installation
- Primary Power Supply
- Secondary Power Supply
- Bell Output
- Keypad Data Bus
- Smoke and Glassbreak Detector Output
- Burglary Zones
- Powered Zone for 2-Wire Smoke Detectors
- Annunciator Outputs
- Telephone RJ Connector
- Ethernet Connector J1
- Reset Header J16
- Flash Load Jumper J18
- Cellular Connections
- On-Board 1100 Series Wireless Antenna Connection
- Wireless Keypads
- Listed Compliance Specifications
- Household Burglar-Alarm System Units ANSI/UL 1023
- Digital Burglar Alarm Communicator System Units ANSI/UL 1635
- Central Station Burglar Alarm Units ANSI/UL 1610
- Household Fire Warning System ANSI/UL 985 NFPA 72 Specifications
- California State Fire Marshal Specifications
- False Alarm Reduction Programmable Options ANSI/SIA CP-01-2010
- Troubleshooting
- Wiring Diagrams
- Revisions to This Document
XT30/XT50 Installation Guide Digital Monitoring Products
17
COMPLIANCE
Listed Compliance Specications
20.1 Introduction
Theprogrammingandinstallationspecicationscontainedinthissectionmustbecompletedwheninstalling
theXT30/XT50inaccordancewithanyoftheANSI/ULburglarystandards.Additionalspecicationsmaybe
required by a particular standard.
20.2 Bypass Reports
ThebypassreportsmustbeprogrammedasYESforalllistedburglaryapplications.
20.3 Current Draw
Thetotalcurrentdrawfromacombinationofauxiliary,smoke,andbelloutputterminalsmustnotexceed
1.6 Amps.
20.4 Battery Standby
UsebatteryModels365(12VDC9Ah)or366(12VDC18Ah)withtheXT30/XT50panelwheninstalledinthe
340,341,349,or349Aenclosures.TheModel364(12VDC1.3Ah)batteryisforusewiththeXT30/XT50
panelwhenusingthe341enclosurewiththeoptional341BBatteryBracket.TheModel364batteryisrated
for4hoursofstandbytime.
20.5 Auxiliary and Bell Current
ForULlistedapplications,themaximumauxiliarycurrentis400mA,andthemaximumbellcurrentis500mA.
20.6 Cross Zoning
Eachzonemusthavethecapabilityofprotectingthecommonareaindividually.
20.7 Software Version
ForULlistedapplications,theminimumsoftwareversionmustbeVersion103.
20.8 App Key
TheRemoteOptionAppKeyhasnotbeenevaluatedforuseinlistedapplications.
Household Burglar-Alarm System Units
ANSI/UL 1023
21.1 Bell Cutoff
The bell cutoff time cannot be less than four minutes.
21.2 Entry Delay
Themaximumentrydelayusedmustnotbemorethan45seconds.
21.3 Exit Delay
The maximum exit delay used must not be more than 60 seconds.
21.4 Wireless External Contact
Whenused,theExternalContactof1101,1102or1105mustbeprogrammedNormallyClosed.
21.5 Wireless Supervision Time
TheZoneInformationSupervisionTimecannotbesetto0(zero).
21.6 Wireless Audible Annunciation
TheWirelessAudibleoptionmustbeselectedasDAYforresidentialapplications.
21.7 Panel location
Mountpanelinsideprotectedarea.
21.8 Test Frequency
TheTestFrequencyoptionmustbeprogrammedtosendareportatleastonceevery30days.
Digital Burglar Alarm Communicator System Units
ANSI/UL 1635
22.1 Entry Delay
The maximum entry delay used must not be more than 60 seconds.
22.2 Exit Delay
The maximum exit delay used must not be more than 60 seconds.
22.3 Test Frequency
TheTestFrequencyoptionmustbeprogrammedtosendareportonceevery24hours.
22.4 Automatic Bell Test
ThisoptionmustbeprogrammedasYES.