User's Manual

Table Of Contents
XT30/XT50 Installation Guide Digital Monitoring Products
1
Panel sPecifications
Panel Specications
1.1 Power Supply
TransformerInput: Plug-in—16.5VAC40VA,Model321
Wire-in—16.5VAC40VA,Model320
StandbyBattery: 12VDC,1.0AmpsMax.chargingcurrent
Models364,365,366,368,or369
Replaceevery3to5years
AuxiliaryOutput: 12VDCat500mA
12VDCat325mAwhenusedwithtwoModel364batteriesintheModel341enclosure
BellOutput: 12VDCat1.5Amps
SmokeDetectorOutput: 12VDCat100mA
All circuits inherent power limited
Note:PleaseseetheListedComplianceSpecicationssectionforcerticatedapplicationrequirements.
1.2 Communication
Built-inSDLCDigitalDialercommunicationtoDMPModelSCS-1RReceivers
Built-innetworkcommunicationtoDMPModelSCS-1RorSCS-VRReceivers
Built-inormodularcellularcommunicationtoDMPModelSCS-1RorSCS-VRReceivers
Built-inCID(ContactID)dialercommunicationtoDMPModelSCS-1RReceivers
1.3 Panel Zones
Nine1kOhmEOLburglaryzones:zones1to9
One3.3kOhmEOLClassBpoweredrezonewithresetcapability:zone10
1.4 Keypads/Expansion
Connectuptoeightsupervisedalphanumerickeypads.
Connectuptofouralphanumeric9000Serieswirelesskeypads.
Eightkeypadstotalperpanel.
Connectadditionalunsupervisedkeypads.
• GraphicTouchscreen,Thinline™,Aqualite™,ClearTouch™,andIconkeypads
Inaddition,thefollowingzoneexpanderscanbeadded:
• One,four,eightand16-zoneexpansionmodules
• Single-zonePIRandglassbreakdetectors
1.5 Number of Zones
• Onboardzones1-10
• Eightkeypadbusaddresseswithzones11-14,21-24,31-34,41-44,51-54,61-64,71-74,and81-84
• Zonenumbers31to34and41to44cansupport1100SeriesKeyFobsorDMPwirelessoutputmodules
• XT50has20additionalonboardwirelesszonesnumbered80-99
1.6 Outputs
TheXT30/XT50panelsprovidefouropencollectoroutputsratedfor50mAeach.AModel300OutputHarness
is required. The open collector outputs provide the ground connection for a positive voltage source.
1.7 Enclosure Specications
TheXT30/XT50panelshipsstandardina340enclosurewithEOLresistors,batteryleads,user’sguide,and
programming sheet.
Enclosure Model Size Color Construction (Cold Rolled Steel)
340 12.5”Wx9.5”Hx2.75”D Gray(G) 20-Gauge
349 12.5”Wx11.5”Hx3.5”D Gray(G) 20-Gauge
349A 13.25”Wx11.65”Hx3.6”D Gray(G) 18-Gaugewith16-Gaugedoor
341 13”Wx6.55”Hx3.5”D Gray(G) 20-Gauge