User's Manual

CellComSL
Series Communicator Install/Programming Guide Digital Monitoring Products
15
COMMUNICATION
Communication
8.1 Communication
TheCommunicationsectionallowsyoutocongurethecommunicationsettingsforthe
CellComSL
SeriesCellularAlarmCommunicator.AfterchoosingtheCommunicationType,
continue through the list of options.
8.2 Account Number
Entertheaccountnumbersenttothereceiver.
CELL-Therangeofaccountnumbersis1to65535.Foraccountnumbersoffourdigits
or less, you do not have to enter leading zeros. The
c
ommunicator automatically right
justiestheaccountnumber.
8.3 Transmission Delay
Enterthenumberofseconds(15to45seconds)thecommunicator waits before sending
burglaryalarmreportstothereceiver.Enter0(zero)todisablethisfunction.The
defaultis30.
IftheareawherethealarmoccurredisdisarmedduringtheTransmitDelaytime,only
anAbortReport(S45)messageissenttothereceiver.Iftheareawherethealarm
occurred is disarmed after the alarm message is sent to the receiver but before the Bell
Cutofftimeexpires,evenifthealarmwassilenced,anAlarmCancelled(S49)messageis
sent.TheAlarmCancelledreportcannotbedisabled.
8.4 Communication Type
The
c
ommunicatorusesCELLcommunicationtoDMPModelSCS-1RorSCS-VRReceivers.
8.5 Test Time
PressCOMMANDtoentertheTestTime.Enterthetimeofdaythecommunicator sends
thetestreporttotheSCS-1RorSCS-VRReceivers.Useentriesbetween12:00to11:59
andthenchooseAMorPM.
8.6 Cell Check In
Check-inreportsareamethodofsupervisingthepanelforcommunicationwiththe
receiver.
Enterthenumberofminutesbetweencheck-inreports.Selectfrom0or3-240minutes.
Enter0(zero)todisablethecheck-inoption.Defaultis0.
Note:IfCellCheck-inoptionisused,additionalcellchargesmayapply.
8.7 Fail Time
FailTimeallowstheSCS-1RorSCS-VRreceivertomissadenednumberofcheck-ins
before logging that the panel is missing. For example, if CELL CHECKIN is20andFAIL
TIMEis30,theSCS-1RreceiveronlyindicatesaPanelNotRespondingafter30minutes.
The FAIL TIME must be equal to or greater than the CELL CHECKIN minutes: If the
CHECKINis20minutes,theFAIL TIME mustbe20ormore.ThemaximumFAIL TIME is
240minutes.Selectfrom0or3-240minutes.ThedefaultFAIL TIME is240minutes.
8.8 Receiver 1 Programming
Allowsyoutosettheoptionsfortherstreceiverthe
c
ommunicator attempts to
contact when sending reports. The
communicator
supports communication to two
receivers.
8.9 Alarm Reports
YESenablesAbort,Alarm,AlarmRestoral,AlarmBellSilenced,Ambush,ExitError,and
SystemRecentlyArmedreportstobesenttothisreceiver.DefaultisYES
8.10 Supervisory/Trouble Reports
YESenablesSupervisory,Trouble,TroubleRestoral,ForceArmed,LatetoClose,and
Faultreportstobesenttothisreceiver.DefaultisYES.
8.11 Opening/Closing and User Reports
YESenablesOpening/Closing,DoorAccess,ScheduleandCodeChanges,andBypass
reportsbyusertobesenttothisreceiver.DefaultisYES.
8.12 Test Report
EnterYEStoenabletheRecallTestreporttobesenttothisreceiver.
8.13 First IP Address
Entertherst(primary)IPaddresswherethe
c
ommunicator sends cell messages. The IP
addressmustbeuniqueandcannotbeduplicatedonthenetwork.Enterall12digitsand
leaveouttheperiods.Forexample,enterIPaddress192.168.0.250as192168000250.
The periods display automatically.
COMMUNICATION
ACCOUNT NO:
XMIT DELAY: 0
COMM TYPE: CELL
TEST TIME
00:00 AM PM
CELL CHECKIN: 0
FAIL TIME: 240
RECEIVER 1 PROG
ALARM NO YES
SPV/TRBL NO YES
O/C USER NO YES
TEST RPT NO YES
FIRST IP ADDR
000.000.000.000