SYSTEM OPTIONS
DuringExitDelay,ifanexitzonetrips,thenrestores,andtripsagain,theExitDelay
timer restarts. This restart can occur only once.
ExitErrorOperation:Atarming,whenanentry/exitzone(EX)isfaultedattheendof
the exit delay then one of two sequences occur:
ForEntryDelayEXtypezones:
• the bell sounds for the length of time set in Bell Cutoff programming
• theEntryDelayoperationstarts,requiringcodeentrytodisarm
• ifnotdisarmed,azonealarmandanExitErroraresenttothereceiver.
12.5 Cross Zone Time
Enterthetimeallowedbetweenzonefaults.Whenazoneprogrammedforcrosszoning
faults, the
c
ommunicatorbeginscountingdowntheCross-ZoneTimeenteredhere.Ifthe
same zone or another cross-zoned zone faults within this time, an alarm report is sent to
the receiver.
IftheCross-ZoneTimeexpireswithoutthesecondzonefault,onlyazonefaultreport
fromtherstzoneissenttothereceiver.TheCross-ZoneTimecanbefrom4to250
secondsinonesecondincrements.Enter0(zero)todisabletheCross-ZoneTimefeature.
SeetheAppendix.
12.6 Power Fail Delay
Thisoptiontracksthedurationofaprimarypowerfailure.Thedelaytimecanbefrom1
to9hours.Whenthepowerisoffforthelengthoftheprogrammeddelaytime,apower
failure report is sent to the receiver. For example, if the power failure delay is set for
twohours,thenthepowerfailurereportwillbesentbetween2-3hours.Enteringa0
(zero) sends the power failure report within 15 seconds.
12.7 Swinger Bypass Trips
Enterthenumberoftimes(1-6)azonecangointoanalarmortroubleconditionwithin
one hour be fore being auto matically bypassed. Bypassed zones are auto matically reset
whentheareatheyareassignedtoisdisarmed.All24-hourzonesareresetwhenany
areaofthesystemisdisarmed.AprogrammingStopoperationrestoresabypassedzone.
Entering0(zero)disablesthisfunction.Defaultis2.
How it works
The communicatorhourtimerstartsat59minutespastthehour.Ifthehourtimer
expiresbeforethetripcounterisexceeded,thetripcounterreturnsto0(zero).Ifthe
trip counter is exceeded before the hour expires, the zone is auto matically bypassed by
the communicator.ABypassReportissenttothereceiverifBypassReportsisYES.
12.8 Reset Swinger Bypass
WhenYESisselected,anautomaticallybypassedzoneisresetifitremainsinanormal
conditionforonecompletehourafterbeingbypassed.Areportoftheautomaticresetis
senttothereceiverifBypassReportshasbeenselectedasYES.DefaultisNO.
12.9 Time Zone Changes
This option allows the communicatortorequestautomatictimechangesfromtheDMP
SCS-1RorSCS-VR Receiver. For the receiver to send time changes, it must be
programmed to send time changes and must be receiving time change updates from the
hostautomationcomputeratleastevery24hours.DefaultisYES.
WhentimezoneisprogrammedYES,enterthenumber(0-23)thatindicatesthe
GreenwichMeanTimezone(GMT)wherethecommunicator is located. The default is 6.
SeetablebelowforGMTvalues.
GMT
City/Time Zone
0
London, Monrovia, Lisbon, Dublin, Casablanca, Edinburgh
1
Cape Verde Island, Azores
2
Mid-Atlantic, Fernando de Noronha
3
Buenos Aires, Georgetown, Brasilia, Rio de Janeiro
4
Atlantic Time (Canada), Caracas, La Paz, Santiago
5
Eastern Time (US, Canada) Bogota, Lima, Arequipa
6
Central Time (US, Canada), Mexico City, Saskatchewan
7
Mountain Time (US, Canada), Edmonton
8
PacicTime(US,Canada),Tijuana
9
Alaska
10
Hawaii
11
Midway Island, Samoa
CRS ZONE TM: 0
PWR FAIL HRS: 1
SWGRBYPS TRIPS: 2
RST SBYP NO YES
TIME CHG NO YES
HRS FROM GMT: 6