User's Manual

Digital Monitoring Products
CellComSL
Series Communicator Install/Programming Guide
20
12
Fiji,MarshallIsland,Wellington,Auckland,Kwajalein,Kamchatka
13 New Cadelonia
14 Guam, Sydney
15 Tokyo, Seoul
16 Hong Kong, Singapore
17 Bangkok, Hanoi
18 Dhaka, Almaty
19 Islamabad, Karachi
20 Abu Dhabi, Kazan
21 Moscow, Bagdad
22 Eastern Europe
23 Rome, Paris, Berlin
12.10 Weather Zip Code
ThisoptionallowslocalU.S.A.weatherupdatestodisplayonthekeypad.Enterthezip
codeoftheuseratthisprompt.Whennonumberisenteredweatherconditionsarenot
displayed.Defaultis0(zero).
Output Options
13.1 Output Options
This section allows you to program
c
ommunicator outputoptions.SwitchedGround
(opencollector)outputsareavailableusingterminalsO1andO2asthegroundandyour
burglary
control panel
forpower.Selectfromoutputs1or2.
13.2 Cutoff Outputs
Thisoptionallowsyoutodenetheoperationofthetwoon-boardoutputs.Foreach
programmingoption,enterthenumberoftheoutputyouwishtoactivateor0(zero)for
nooutput.Eitherorbothoftheavailableoutputscanbeprogrammedheretoturnoff
afterthetimespeciedinOutputCutoffTime.Todisablethisoption,pressanySelect
keytoclearthedisplayofoutputnumbersandthenpressCOMMAND.
13.2.1 Output Cutoff Time
IfaCutoffOutputisassigned,youcanenteraCutoffTimefortheoutputtoremain
on up to 15 minutes. If the output is turned off manually, the cut off time is reset. The
CutoffTimecanbe1-15minutes.Enter0(zero)toprovidecontinuousoutput.
Note:Theoutputiscutoffwithin60secondsoftheprogrammedcutofftime.
The Cutoff Timer is shared by all outputs. If a second output trips, the timer is not
reset. Both outputs turn off when the original time expires.
13.3 Communication Failure Output
ThisOutput/Favoriteturnsonwhenthe
c
ommunicator fails to communicate with the
receiverafterthreesuccessivedialattempts.Enter0(zero)todisablethisoutput.To
turnofftheCommunicationFailureOutput,disarmthecommunicator.
Note:FavoritesareonlyavailableontheCellComSLCZCommunicator.
13.4 Armed Output
ThisOutput/Favoriteturnsonanytimeanareaofthesystemisarmed.Theoutputturns
offwhenthesystemcompletelydisarms.Enter0(zero)todisablethisoutput.
13.5 Heat Saver Temperature (
CellComSL
CZ only)
EnterthedesiredtemperaturesettingforallZ-Wavethermostatswhenthesystem
isarmedALLorAWAY.Whenthesystemisdisarmedthethermostatsreturntotheir
previoussettings.Therangeis55-95degrees.Enter0(zero)todisable.
13.6 Cool Saver Temperature (
CellComSL
CZ only)
EnterthedesiredtemperaturesettingforallZ-Wavethermostatswhenthesystem
isarmedALLorAWAY.Whenthesystemisdisarmedthethermostatsreturntotheir
previoussettings.Therangeis55-95degrees.Enter0(zero)todisable.
ENTER WEATHER
ZIP CODE: 0
OUTPUT OPTIONS
CO OUTS: - - -
CUTOFF TIME: 0
COM FAIL OUT: 0
ARMED OUT: 0
HEAT SAVER
TEMPERATURE: 0
COOL SAVER
TEMPERATURE: 0
SYSTEM OPTIONS
OUTPUT OPTIONS