User's Manual
Digital Monitoring Products
CellComSL
Series Communicator Install/Programming Guide
20
12
Fiji,MarshallIsland,Wellington,Auckland,Kwajalein,Kamchatka
13 New Cadelonia
14 Guam, Sydney
15 Tokyo, Seoul
16 Hong Kong, Singapore
17 Bangkok, Hanoi
18 Dhaka, Almaty
19 Islamabad, Karachi
20 Abu Dhabi, Kazan
21 Moscow, Bagdad
22 Eastern Europe
23 Rome, Paris, Berlin
12.10 Weather Zip Code
ThisoptionallowslocalU.S.A.weatherupdatestodisplayonthekeypad.Enterthezip
codeoftheuseratthisprompt.Whennonumberisenteredweatherconditionsarenot
displayed.Defaultis0(zero).
Output Options
13.1 Output Options
This section allows you to program
c
ommunicator outputoptions.SwitchedGround
(opencollector)outputsareavailableusingterminalsO1andO2asthegroundandyour
burglary
control panel
forpower.Selectfromoutputs1or2.
13.2 Cutoff Outputs
Thisoptionallowsyoutodenetheoperationofthetwoon-boardoutputs.Foreach
programmingoption,enterthenumberoftheoutputyouwishtoactivateor0(zero)for
nooutput.Eitherorbothoftheavailableoutputscanbeprogrammedheretoturnoff
afterthetimespeciedinOutputCutoffTime.Todisablethisoption,pressanySelect
keytoclearthedisplayofoutputnumbersandthenpressCOMMAND.
13.2.1 Output Cutoff Time
IfaCutoffOutputisassigned,youcanenteraCutoffTimefortheoutputtoremain
on up to 15 minutes. If the output is turned off manually, the cut off time is reset. The
CutoffTimecanbe1-15minutes.Enter0(zero)toprovidecontinuousoutput.
Note:Theoutputiscutoffwithin60secondsoftheprogrammedcutofftime.
The Cutoff Timer is shared by all outputs. If a second output trips, the timer is not
reset. Both outputs turn off when the original time expires.
13.3 Communication Failure Output
ThisOutput/Favoriteturnsonwhenthe
c
ommunicator fails to communicate with the
receiverafterthreesuccessivedialattempts.Enter0(zero)todisablethisoutput.To
turnofftheCommunicationFailureOutput,disarmthecommunicator.
Note:FavoritesareonlyavailableontheCellComSLCZCommunicator.
13.4 Armed Output
ThisOutput/Favoriteturnsonanytimeanareaofthesystemisarmed.Theoutputturns
offwhenthesystemcompletelydisarms.Enter0(zero)todisablethisoutput.
13.5 Heat Saver Temperature (
CellComSL
CZ only)
EnterthedesiredtemperaturesettingforallZ-Wavethermostatswhenthesystem
isarmedALLorAWAY.Whenthesystemisdisarmedthethermostatsreturntotheir
previoussettings.Therangeis55-95degrees.Enter0(zero)todisable.
13.6 Cool Saver Temperature (
CellComSL
CZ only)
EnterthedesiredtemperaturesettingforallZ-Wavethermostatswhenthesystem
isarmedALLorAWAY.Whenthesystemisdisarmedthethermostatsreturntotheir
previoussettings.Therangeis55-95degrees.Enter0(zero)todisable.
ENTER WEATHER
ZIP CODE: 0
OUTPUT OPTIONS
CO OUTS: - - -
CUTOFF TIME: 0
COM FAIL OUT: 0
ARMED OUT: 0
HEAT SAVER
TEMPERATURE: 0
COOL SAVER
TEMPERATURE: 0
SYSTEM OPTIONS
OUTPUT OPTIONS