User's Manual

CellComSL
Series Communicator Install/Programming Guide Digital Monitoring Products
21
AREA INFORMATION
Area Information
14.1 Area Information
This section allows you to assign functions to the burglary area of the communicator.
Allnon-24-hourzonesmustbeassignedtoanactivearea.SeethesectiononZone
Information.
14.2 Area Number
OnlyArea1isavailabletoprogram.
14.3 Area Name
DefaultAreaNameisAREA1.Tochangetheareanameinthesystem,pressanySelect
keyandthenenterupto16charactersforthenewname.PressCOMMANDtocontinue.
RefertotheEnteringAlphaCharacterssection.
14.4 Automatic Arming
SelectYEStoallowthisareatoarmautomaticallyaccordingtotheopeningandclosing
schedule.
IfClosingCheckisselectedasYES,theautomaticarmingdoesnottakeplaceuntilthe
expirationofa10-minuteClosingCheckdelay.Iftheareahasbeendisarmedoutsidea
schedule,theClosingCheckdelayoccursonehouraftertheareaisdisarmed.
Atarming,faultedzonesarehandledaccordingtotheoptionselectedinBadZones.If
aClosingreportissent,theusernumberisindicatedasSCHontheSCS-1RorSCS-VR
Receivers.SelectNOtodisableautomaticarmingforthisarea.DefaultisNO.
14.5 Automatic Disarming
NOdisablesautomaticdisarmingbyscheduleforthisarea.SelectYEStoallowthisarea
toautomaticallydisarmaccordingtoaschedule.IfanOpeningreportissenttothe
receiver,theusernumberisindicatedasSCH.
Zone Information
15.1 Zone Information
Thisallowsyoutodenetheoperationofeachprotectionzoneusedinthesystem.
15.2 Zone Number
The
c
ommunicatorhasfourzonestoprogram.Enterthenumberofthezoneyouintend
toprogram.PressCOMMANDtoenterazonename.RefertotheEnterAlphaCharacters
section.
15.3 Zone Name
PressanySelectkeyandenterupto16charactersforthezonename.Anamemustbe
giventoeachzoneinthesystem.Thisnamecanbedisplayedatthekeypadswhenthe
zoneisbadorviewedinDisplayEvents.Thezonenameisalsosenttothereceiveras
part of a zone event report.
Azonethatisnotpartofthesystemmustbemarked*UNUSED*.Tomarkazoneunused,
deletetheoldnamebypressinganySelectkey,thenpresstheCOMMANDkey.Thepro-
grammerautomaticallyprogramsthenameas*UNUSED*.IfyouselectedZONES?NO
YEStoclearthecommunicatorsmemoryduringInitialization,thezoneswillalreadybe
marked*UNUSED*.SeetheInitializationsection.
15.4 Zone Type
TheZoneTypedenestheresponseofthecommunicator to the zone being open or
short.RefertotheAppendixforzonetypedefaultsanddescriptions.
WhenyouassignaZoneTypetoazone,responsesaremadeautomaticallyforthezone.
Thereare11ZoneTypestochoosefromincludingBlank.Thefunctionaldetailsofeach
responsearedescribedinZoneTypeDefaultsintheAppendix.
ToselectanewZoneType,pressanySelectkey.ThedisplayliststhefourZoneTypes
shownbelow.WhentheZoneTypeyouwanttoselectdisplays,presstheSelectkey
below the name.
Blank,Night,Day,orExit.PressCOMMANDtodisplayadditionalzonetypes.
Fire,Panic,Emergency,orSupervisory.PressCOMMANDtodisplayadditionalzonetypes.
Auxiliary1,Auxiliary2,FireVerify,orArming.PresstheBackArrowkeytodisplaythe
previous zone types.
IfyouselectBlank,Night,Day,Exit,Auxiliary1,orAuxiliary2astheZoneType,the
zonemustbeassignedtoanarea.IfyouselectFire,Panic,Emergency,orSupervisoryas
theZoneType,theseare24-hourzonesthatarealwaysarmedandnoareaassignmentis
needed.PressCOMMANDtocontinue.
RefertotheAppendixforzonetypespecicationsanddescriptions.
AREA INFORMATION
AREA 1
AUTO ARM NO YES
AUTO DIS NO YES
ZONE INFORMATION
ZONE NO: -
* UNUSED *
ZONE TYPE: BLANK
ZONE INFORMATION
A1 A2 AR FV
FI PN EM SV
AREA NO: -
-- NT DY EX