User's Manual

Digital Monitoring Products
CellComSL
Series Communicator Install/Programming Guide
26
APPENDIX
WALK TEST
TRIPS: XXX END
Activate Cell
To begin the cellular activation for a
c
ommunicator,verifythattheMEIDhasbeenaddedforthe
communicator
usingRemoteLinkorbycallingCustomerService(1-800-641-4282).Atthekeypad,pressanytoprowSelectkey
when ACTIVATE CELLisdisplayedonthekeypad.WhentheSURE NO YES?conrmationmenuappearspressthe
SelectkeybeneathYEStocompletethecellularactivation.
Successful Display Failure Display
CELL ACTIVATED NOT ACTIVATED
Panel Settings
PressingatoprowkeyallowsaccesstotheMACAddress,SerialNumber,Model,andFirmwareVersion.
Serial Number
This number is the communicator serial number. Reference this number for communicator date-of-manufacture,
hardwareversion,etc.PressanytoprowSelectkeytodisplaytheSerialNumber.
Model Number
This menu option displays the model number of the
communicator
.
Firmware Version
Thismenuoptiondisplaysthermwareversionnumberofthe
communicator
and date it was released.
Z-Wave Test Option
This feature allows the installer to test
CellComSL
CZcommunicationwithZ-Wave
devices.Asuccessfultestindicatesaresponsefromadevice.PressanytoprowSelect
keytoviewtheZ-WaveDeviceList.
PressCOMMANDtoadvancethrougheachZ-WavedeviceandpressanytoprowSelect
keytobeginthetestonthedevicedisplayed.
The name of the device displays above the device number. The current number of
successful communications followed by the total number of attempts displays to the
rightofthedevicenumber.Theteststopsafter99attempts.
PressCOMMANDtoviewthenalnumberofsuccessfulcommunications.
Exiting the Diagnostics program
PresstheCOMMANDkeyuntilSTOPdisplays.PressanySelectkey.ThekeypadreturnstotheStatusListdisplay.
18.4 Using the 984 Command Function
WhennotintheProgrammingMenu,thefunction984+COMMANDcanbeenteredatthekeypad,andaremote
options menu appears. This menu contains the following options:
CELL
Thecommunicatorallowsyoutoperformatestoneachcomponentofthecellularcommunicationpaths.While
theStatusListdisplays,enter984andpresstheCOMMANDkey.PresstheSelectkeyunder CELL to allow the
communicatortoperformaCommunicationStatusTest.ThekeypaddisplaysCELL IS BUSY if the modem is being
testedfromanotherkeypad.
UponentryofaCellularpathwhenprompted,thetestrunsandtheresultsdisplayonthekeypadintheorderthey
weretested:MODEMOPERATING,IDENTIFIED,TOWERDETECTED,REGISTERED,CONNECTSUCCESS,andCELLCOM
GOOD.PressCOMMANDtoadvancethroughtheresults.WhenthetestiscompleteyouarereturnedtotheStatus
List.SeetheDiagnosticFunctionssectionforadescriptionoftheCellularStatusresults.
18.5 Using the Walk Test
Thecommunicatorprovidesawalktestfeaturethatallowsasingletechniciantotestalltheprotectiondevices
connectedtozonesonthesystem.ConducttheWalkTestwithin30minutesofresettingthecommunicator.The
WalkTestautomaticallyendsifnozonesaretrippedfor20minutes.TEST IN PROGRESSdisplaysatallkeypads.
Whenveminutesremain,TEST END WARNINGdisplays.IfanyareasarearmedtheWalkTestdoesnotstartand
SYSTEM ARMED displays.
Walk Test
ToconducttheWalkTest,resetthecommunicatorbymomentarilypressingtheRESET
button.Fromthekeypad,enterthecode8144.ThekeypaddisplaysWALK TEST. If the
systemismonitored,thesystemsendsaSystemTestBeginreporttothecentralstation.
Allprogrammedzonesareincludedinthetest.
Trip Counter for Walk Test (STD)
DisplaysthenumberofzonetripsduringtheWalkTest.
• Eachtimeaselectedzonetrips,thekeypadbuzzesandthebellringsfortwo
seconds.
TEST ZWAVE
DEVICE LIST:
HALLWAY LIGHT
HALLWAY LIGHT
LIGHT 02 0/0
HALLWAY LIGHT
99/99 SUCCESSFUL
WALK TEST